Unknown

Dataset Information

0

Subjective Comparison of Pre-Lens Tear Film Stability of Daily Disposable Contact Lenses Using Ring Mire Projection.


ABSTRACT: Purpose:To subjectively evaluate the in vivo tear film stability of three daily disposable contact lenses (DDCLs) using placido ring reflection at lens wear times of 5 mins and 8 and 12 hrs. Patients and Methods:This prospective, randomized, observer-masked, 3-way crossover study evaluated 28 subjects with good tear film stability. In vivo tear film stability was assessed for three DDCLs (nelfilcon A, etafilcon A, omafilcon A) on three different days over 12 hrs of lens wear. Time to first distortion by non-invasive keratography drying-up time (NIK-DUTf) was assessed by reviewing the captured videos. Lens wettability was also graded subjectively by three investigators using a scale from 0 (no visible distortions) to 3 (distortions in more than one-third of the ring reflection zone). Medians were analyzed statistically. Results:Mean NIKDUTf at 8 hrs was longer for nelfilcon A and shorter for etafilcon A and omafilcon A, but the differences were not significant. NIK-DUTf did not differ significantly among nelfilcon A, etafilcon A and omafilcon A DDCLs at all visits (p=0.36). Subjective wettability grades after 5 mins, 8 hrs, and 12 hrs differed significantly for etafilcon A (P <0.01) and omafilcon A (p < 0.01), but not for nelfilcon A (p = 0.05), DDCLs. Conclusion:Grading was sufficiently sensitive to differentiate the wettability performances of the three lens materials. Nelfilcon A maintained wettability over the wearing period, whereas etafilcon A material showed faster dewetting at 8 and 12 hrs than at 5 mins after lens insertion.

SUBMITTER: Muller C 

PROVIDER: S-EPMC7053817 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Subjective Comparison of Pre-Lens Tear Film Stability of Daily Disposable Contact Lenses Using Ring Mire Projection.

Müller Christiane C   Marx Sebastian S   Wittekind Julia J   Sickenberger Wolfgang W  

Clinical optometry 20200228


<h4>Purpose</h4>To subjectively evaluate the in vivo tear film stability of three daily disposable contact lenses (DDCLs) using placido ring reflection at lens wear times of 5 mins and 8 and 12 hrs.<h4>Patients and methods</h4>This prospective, randomized, observer-masked, 3-way crossover study evaluated 28 subjects with good tear film stability. In vivo tear film stability was assessed for three DDCLs (nelfilcon A, etafilcon A, omafilcon A) on three different days over 12 hrs of lens wear. Time  ...[more]

Similar Datasets

| S-EPMC3972648 | biostudies-literature
| S-EPMC8203656 | biostudies-literature
| S-EPMC5558933 | biostudies-literature
| S-EPMC8565979 | biostudies-literature
| S-EPMC4140805 | biostudies-literature
| S-EPMC8165404 | biostudies-literature
| S-EPMC4689550 | biostudies-literature
| S-EPMC8302406 | biostudies-literature
| S-EPMC8146472 | biostudies-literature