Unknown

Dataset Information

0

Thoracic ultrasound evaluation and B-type natriuretic peptide value in elective cesarean section under spinal anesthesia.


ABSTRACT: BACKGROUND:Pregnancy-induced changes in cardiovascular status make women more susceptible to pulmonary edema. During cesarean section, to counterbalance the effect of hypotension caused by spinal anesthesia, anesthesiologists must choose between two fundamental approaches to maintain the hemodynamic state-intravenous fluids or vasopressors-and this choice will depend upon their particular opinions and experience. We aim to assess for any correlations between thoracic ultrasound A- and B-line artifacts, brain natriuretic peptide (BNP) levels, and the amount of intraoperative fluids administered. RESULTS:From December 2016 to August 2018, at the University-Hospital of Udine, we enrolled 80 consecutive pregnant women undergoing cesarean section. We observed a statistically significant difference in the volume of fluids administered in the first 24 h (p?=?0.035) between the patients presenting B-lines in at least one basal area of their thoracic ultrasound and patients with no evident B-lines (AUC 66.4%; IC 0.49-0.83). Dividing the population on whether their BNP levels were higher or less than 20 pg/mL, no statistically significant difference was revealed with regard to fluids administered in the first 24 h (p?=?0.537). CONCLUSIONS:Thoracic ultrasound is a non-invasive and easy-to-use tool for detecting fluid intolerance in pregnant women undergoing cesarean section. BNP levels were slow to rise following the cesarean section and did not show any clear correlation with fluid volumes administered.

SUBMITTER: Vetrugno L 

PROVIDER: S-EPMC7058737 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Thoracic ultrasound evaluation and B-type natriuretic peptide value in elective cesarean section under spinal anesthesia.

Vetrugno Luigi L   Dogareschi Teresa T   Sassanelli Rossella R   Orso Daniele D   Seremet Ludmilla L   Mattuzzi Lisa L   Scapol Sara S   Spasiano Alessandra A   Cagnacci Angelo A   Bove Tiziana T  

The ultrasound journal 20200306 1


<h4>Background</h4>Pregnancy-induced changes in cardiovascular status make women more susceptible to pulmonary edema. During cesarean section, to counterbalance the effect of hypotension caused by spinal anesthesia, anesthesiologists must choose between two fundamental approaches to maintain the hemodynamic state-intravenous fluids or vasopressors-and this choice will depend upon their particular opinions and experience. We aim to assess for any correlations between thoracic ultrasound A- and B-  ...[more]

Similar Datasets

| S-EPMC3950466 | biostudies-literature
| S-EPMC8216363 | biostudies-literature
| S-EPMC5559702 | biostudies-literature
| S-EPMC6330402 | biostudies-literature
| S-EPMC6625299 | biostudies-literature
2009-11-02 | GSE18850 | GEO
| S-EPMC5548943 | biostudies-other
| S-EPMC8774980 | biostudies-literature
| S-EPMC8104294 | biostudies-literature
| S-EPMC8666525 | biostudies-literature