Unknown

Dataset Information

0

Optimal mean airway pressure during high-frequency oscillatory ventilation in an experimental model of acute respiratory distress syndrome: EIT-based method.


ABSTRACT: BACKGROUND:High-frequency oscillatory ventilation (HFOV) may theoretically provide lung protective ventilation. The negative clinical results may be due to inadequate mean airway pressure (mPaw) settings in HFOV. Our objective was to evaluate the air distribution, ventilatory and hemodynamic effects of individual mPaw titration during HFOV in ARDS animal based on oxygenation and electrical impedance tomography (EIT). METHODS:ARDS was introduced with repeated bronchoalveolar lavage followed by injurious mechanical ventilation in ten healthy male pigs (51.2?±?1.9 kg). Settings of HFOV were 9 Hz (respiratory frequency), 33% (inspiratory time) and 70 cmH2O (?pressure). After lung recruitment, the mPaw was reduced in steps of 3 cmH2O every 6 min. Hemodynamics and blood gases were obtained in each step. Regional ventilation distribution was determined with EIT. RESULTS:PaO2/FiO2 decreased significantly during the mPaw decremental phase (p?

SUBMITTER: Liu S 

PROVIDER: S-EPMC7060304 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Optimal mean airway pressure during high-frequency oscillatory ventilation in an experimental model of acute respiratory distress syndrome: EIT-based method.

Liu Songqiao S   Zhao Zhanqi Z   Tan Li L   Wang Lihui L   Möller Knut K   Frerichs Inéz I   Yu Tao T   Huang Yingzi Y   Pan Chun C   Yang Yi Y   Qiu Haibo H  

Annals of intensive care 20200306 1


<h4>Background</h4>High-frequency oscillatory ventilation (HFOV) may theoretically provide lung protective ventilation. The negative clinical results may be due to inadequate mean airway pressure (mPaw) settings in HFOV. Our objective was to evaluate the air distribution, ventilatory and hemodynamic effects of individual mPaw titration during HFOV in ARDS animal based on oxygenation and electrical impedance tomography (EIT).<h4>Methods</h4>ARDS was introduced with repeated bronchoalveolar lavage  ...[more]

Similar Datasets

| S-EPMC7347764 | biostudies-literature
| S-EPMC4114308 | biostudies-literature
| S-EPMC6668751 | biostudies-literature
| S-EPMC9990689 | biostudies-literature
| S-EPMC6001134 | biostudies-literature
| S-EPMC9039831 | biostudies-literature
| S-EPMC8205213 | biostudies-literature
| S-EPMC6995130 | biostudies-literature
| S-EPMC2887141 | biostudies-literature
| S-EPMC4128514 | biostudies-literature