Individual Ion Mass Spectrometry Enhances the Sensitivity and Sequence Coverage of Top-Down Mass Spectrometry.


ABSTRACT: Charge detection mass spectrometry (CDMS) is mainly utilized to determine the mass of intact molecules. Previous applications of CDMS have determined the mass-to-charge ratio and the charge of large polymers, DNA molecules, and native protein complexes, from which corresponding mass values could be assigned. Recent advances have demonstrated that CDMS using an Orbitrap mass analyzer yields the reliable assignment of integer charge states that enables individual ion mass spectrometry (I2MS) and spectral output directly into the mass domain. Here I2MS analysis was extended to isotopically resolved fragment ions from intact proteoforms for the first time. With a radically different bias for ion readout, I2MS identified low-abundance fragment ions containing many hundreds of residues that were undetectable by standard Orbitrap measurements, leading to a doubling in the sequence coverage of triosephosphate isomerase. Thus MS/MS with the detection of individual ions (MS/I2MS) provides a far greater ability to detect high mass fragment ions and exhibits strong complementarity to traditional spectral readout in this, its first application to top-down mass spectrometry.

SUBMITTER: Kafader JO 

PROVIDER: S-EPMC7060802 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Individual Ion Mass Spectrometry Enhances the Sensitivity and Sequence Coverage of Top-Down Mass Spectrometry.

Kafader Jared O JO   Durbin Kenneth R KR   Melani Rafael D RD   Des Soye Benjamin J BJ   Schachner Luis F LF   Senko Michael W MW   Compton Philip D PD   Kelleher Neil L NL  

Journal of proteome research 20200211 3


Charge detection mass spectrometry (CDMS) is mainly utilized to determine the mass of intact molecules. Previous applications of CDMS have determined the mass-to-charge ratio and the charge of large polymers, DNA molecules, and native protein complexes, from which corresponding mass values could be assigned. Recent advances have demonstrated that CDMS using an Orbitrap mass analyzer yields the reliable assignment of integer charge states that enables individual ion mass spectrometry (I<sup>2</su  ...[more]

Similar Datasets

| S-EPMC9090460 | biostudies-literature
| S-EPMC7845485 | biostudies-literature
| S-EPMC10032035 | biostudies-literature
| S-EPMC6071867 | biostudies-literature
| S-EPMC5826643 | biostudies-literature
| S-EPMC10372872 | biostudies-literature
| S-EPMC3908771 | biostudies-literature
| S-EPMC2131703 | biostudies-literature
| S-EPMC5825287 | biostudies-literature
| S-EPMC6805827 | biostudies-other