ABSTRACT: Background
Studies on the efficacy of implantable cardioverter-defibrillator (ICD) therapy for primary prevention in Asian patients are relatively lacking compared to those for secondary prevention. Also, it is important to stratify which patients will benefit from ICD therapy for primary prevention.Methods
Of 483 consecutive patients who received new implantation of ICD in 9 centers in Korea, 305 patients with reduced left ventricular systolic function and/or documented ventricular fibrillation/tachycardia were enrolled and divided into primary (n = 167) and secondary prevention groups (n = 138).Results
During mean follow-up duration of 2.6 ± 1.6 years, appropriate ICD therapy occurred in 78 patients (25.6%), and appropriate ICD shock and anti-tachycardia pacing occurred in 15.1% and 15.1% of patients, respectively. Appropriate ICD shock rate was not different between the two groups (primary 12% vs. secondary 18.8%, P = 0.118). However, appropriate ICD therapy rate including shock and anti-tachycardia pacing was significantly higher (primary 18% vs. secondary 34.8%, P = 0.001) in the secondary prevention group. Type of prevention and etiology, appropriate and inappropriate ICD shock did not affect all-cause death. High levels of N-terminal pro-B-type natriuretic peptide, New York Heart Association functional class, low levels of estimated glomerular filtration ratio, and body mass index were associated with death before appropriate ICD shock in the primary prevention group. When patients were categorized in 5 risk score groups according to the sum of values defined by each cut-off level, significant differences in death rate before appropriate ICD shock were observed among risk 0 (0%), 1 (3.6%), 2 (3%), 3 (26.5%), and 4 (40%) (P < 0.001).Conclusion
In this multicenter regional registry, the frequency of appropriate ICD therapy is not low in the primary prevention group. In addition, combination of poor prognostic factors of heart failure is useful in risk stratification of patients who are not benefiting from ICD therapy for primary prevention.
SUBMITTER: Bae MH
PROVIDER: S-EPMC7061144 | biostudies-literature | 2020 Mar
REPOSITORIES: biostudies-literature
Bae Myung Hwan MH Cho Yongkeun Y Hwang Jongmin J Park Hyoung Seob HS Han Seongwook S Lee Young Soo YS Cho Hyun Jun HJ Jung Byung Chun BC Lee Chan Hee CH Hyun Dae Woo DW Park Jong Sung JS Ahn Jinhee J Kim Ki Hun KH Shin Dong Gu DG
Journal of Korean medical science 20200309 9
<h4>Background</h4>Studies on the efficacy of implantable cardioverter-defibrillator (ICD) therapy for primary prevention in Asian patients are relatively lacking compared to those for secondary prevention. Also, it is important to stratify which patients will benefit from ICD therapy for primary prevention.<h4>Methods</h4>Of 483 consecutive patients who received new implantation of ICD in 9 centers in Korea, 305 patients with reduced left ventricular systolic function and/or documented ventricu ...[more]