Unknown

Dataset Information

0

Updated Australian diagnostic reference levels for adult CT.


ABSTRACT: INTRODUCTION:In 2018, ARPANSA published updated national DRLs for adult CT, which were first published in 2012, and augmented the national DRL categories. This paper presents the updated national DRLs and describes the process by which they were produced. METHODS:Examine patient survey data submitted to the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) National Diagnostic Reference Level Service (NDRLS). Determine the quartiles of the distributions of median survey dose metrics with categorisation by procedure type. Engage a liaison panel representing the radiology professions to review procedure categories and recommend revised national DRLs. The revised NDRL procedure categories are: head (non-contrast brain (trauma/headache)), cervical spine (Non-contrast (trauma)), soft-tissue neck (post-contrast (oncology)), chest (post-contrast (oncology)), abdomen-pelvis (post-contrast (oncology)), kidney-ureter-bladder (non-contrast (suspected renal colic)), chest-abdomen-pelvis (post-contrast (oncology)) and lumbar spine (non-contrast (degenerative pain)). RESULTS:The existing six procedure categories were revised and refined. Updated Australian national diagnostic reference levels for adult CT were recommended and endorsed for eight procedure categories: head (52 mGy/880 mGycm), cervical spine (23 mGy/470 mGycm),soft-tissue neck (17 mGy/450 mGycm), chest (10 mGy/390 mGycm), abdomen-pelvis (13 mGy/600 mGycm), kidney-ureter-bladder (13 mGy/600 mGycm), chest-abdomen-pelvis (11 mGy/940 mGycm) and lumbar spine (26 mGy/670 mGycm). The updated national DRLs are between 12 and 26% lower than the previous DRLs for dose-length product and between 13 and 63% lower for volume computed tomography dose index. CONCLUSIONS:Australian national DRLs for adult CT have been reviewed and revised. The revised national DRLs are lower, better reflecting current practice among imaging facilities in Australia. The revised Australian national DRLs are similar to those in other developed countries.

SUBMITTER: Lee KL 

PROVIDER: S-EPMC7063242 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Updated Australian diagnostic reference levels for adult CT.

Lee Kam L KL   Beveridge Toby T   Sanagou Masoumeh M   Thomas Peter P  

Journal of medical radiation sciences 20200210 1


<h4>Introduction</h4>In 2018, ARPANSA published updated national DRLs for adult CT, which were first published in 2012, and augmented the national DRL categories. This paper presents the updated national DRLs and describes the process by which they were produced.<h4>Methods</h4>Examine patient survey data submitted to the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) National Diagnostic Reference Level Service (NDRLS). Determine the quartiles of the distributions of median  ...[more]

Similar Datasets

| S-EPMC9830915 | biostudies-literature
| S-EPMC10079797 | biostudies-literature
| S-EPMC8831291 | biostudies-literature
| S-EPMC8437305 | biostudies-literature
| PRJEB22249 | ENA
| S-EPMC8236355 | biostudies-literature
| S-EPMC10297281 | biostudies-literature
| S-EPMC7725139 | biostudies-literature
| S-EPMC6768896 | biostudies-literature
| S-EPMC9887267 | biostudies-literature