Unknown

Dataset Information

0

Comparison of Liquid Chromatography Mass Spectrometry and Enzyme-Linked Immunosorbent Assay Methods to Measure Salivary Cotinine Levels in Ill Children.


ABSTRACT: Objective: Cotinine is the preferred biomarker to validate levels of tobacco smoke exposure (TSE) in children. Compared to enzyme-linked immunosorbent assay methods (ELISA) for quantifying cotinine in saliva, the use of liquid chromatography tandem mass spectrometry (LC-MS/MS) has higher sensitivity and specificity to measure very low levels of TSE. We sought to compare LC-MS/MS and ELISA measures of cotinine in saliva samples from children overall and the associations of these measures with demographics and TSE patterns. Method: Participants were nonsmoking children (N = 218; age mean (SD) = 6.1 (5.1) years) presenting to a pediatric emergency department. Saliva samples were analyzed for cotinine using both LC-MS/MS and ELISA. Limit of quantitation (LOQ) for LC-MS/MS and ELISA was 0.1 ng/ml and 0.15 ng/ml, respectively. Results: Intraclass correlations (ICC) across methods = 0.884 and was consistent in sex and age subgroups. The geometric mean (GeoM) of LC-MS/MS = 4.1 (range: < LOQ - 382 ng/mL; 3% < LOQ) which was lower (p < 0.0001) than the ELISA GeoM = 5.7 (range: < LOQ - 364 ng/mL; 5% < LOQ). Similar associations of cotinine concentrations with age ( < -0.10, p < 0.0001), demographic characteristics (e.g., income), and number of cigarettes smoked by caregiver ( > 0.07, p < 0.0001) were found regardless of cotinine detection method; however, cotinine associations with sex and race/ethnicity were only found to be significant in models using LC-MS/MS-derived cotinine. Conclusions: Utilizing LC-MS/MS-based cotinine, associations of cotinine with sex and race/ethnicity of child were revealed that were not detectable using ELISA-based cotinine, demonstrating the benefits of utilizing the more sensitive LC-MS/MS assay for cotinine measurement when detecting low levels of TSE in children.

SUBMITTER: Mahabee-Gittens EM 

PROVIDER: S-EPMC7068296 | biostudies-literature | 2020 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of Liquid Chromatography Mass Spectrometry and Enzyme-Linked Immunosorbent Assay Methods to Measure Salivary Cotinine Levels in Ill Children.

Mahabee-Gittens E Melinda EM   Mazzella Matthew J MJ   Doucette John T JT   Merianos Ashley L AL   Stone Lara L   Wullenweber Chase A CA   A Busgang Stefanie S   Matt Georg E GE  

International journal of environmental research and public health 20200212 4


<b>Objective</b>: Cotinine is the preferred biomarker to validate levels of tobacco smoke exposure (TSE) in children. Compared to enzyme-linked immunosorbent assay methods (ELISA) for quantifying cotinine in saliva, the use of liquid chromatography tandem mass spectrometry (LC-MS/MS) has higher sensitivity and specificity to measure very low levels of TSE. We sought to compare LC-MS/MS and ELISA measures of cotinine in saliva samples from children overall and the associations of these measures w  ...[more]

Similar Datasets

| S-EPMC8051755 | biostudies-literature
| S-EPMC4615133 | biostudies-literature
| S-EPMC6089938 | biostudies-literature
| S-EPMC4663146 | biostudies-literature
| S-EPMC3957675 | biostudies-literature
| S-EPMC7139616 | biostudies-literature
| S-EPMC4966666 | biostudies-literature
| S-EPMC8479797 | biostudies-literature
| S-EPMC4439212 | biostudies-literature
| S-EPMC6311459 | biostudies-literature