Comparison of echocardiographic and invasive measures of volaemia and cardiac performance in critically ill patients.


ABSTRACT: Echocardiographic measurements are used in critical care to evaluate volume status and cardiac performance. Mean systemic filling pressure and global heart efficiency measures intravascular volume and global heart function. This prospective study conducted in fifty haemodynamically stabilized, mechanically ventilated patients investigated relationships between static echocardiographic variables and estimates of global heart efficiency and mean systemic filling pressure. Results of univariate analysis demonstrated weak correlations between left ventricular end-diastolic volume index (r?=?0.27, p?=?0.04), right atrial volume index (rho = 0.31, p?=?0.03) and analogue mean systemic filling pressure; moderate correlations between left ventricular ejection fraction (r?=?0.31, p?=?0.03), left ventricular global longitudinal strain (r?=?0.36, p?=?0.04), tricuspid annular plane systolic excursion (rho = 0.37, p?=?0.01) and global heart efficiency. No significant correlations were demonstrated by multiple regression. Mean systemic filling pressure calculated with cardiac output measured by echocardiography demonstrated good agreement and correlation with invasive techniques (bias 0.52?±?1.7?mmHg, limits of agreement -2.9 to 3.9?mmHg, r?=?0.9, p?

SUBMITTER: Yastrebov K 

PROVIDER: S-EPMC7078248 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of echocardiographic and invasive measures of volaemia and cardiac performance in critically ill patients.

Yastrebov Konstantin K   Aneman Anders A   Schulz Luis L   Hamp Thomas T   McCanny Peter P   Parkin Geoffrey G   Myburgh John J  

Scientific reports 20200317 1


Echocardiographic measurements are used in critical care to evaluate volume status and cardiac performance. Mean systemic filling pressure and global heart efficiency measures intravascular volume and global heart function. This prospective study conducted in fifty haemodynamically stabilized, mechanically ventilated patients investigated relationships between static echocardiographic variables and estimates of global heart efficiency and mean systemic filling pressure. Results of univariate ana  ...[more]

Similar Datasets

| S-EPMC8166586 | biostudies-literature
| S-EPMC10193331 | biostudies-literature
| S-EPMC2039828 | biostudies-other
| S-EPMC10030437 | biostudies-literature
| S-EPMC6743193 | biostudies-literature
| S-EPMC8255172 | biostudies-literature
2022-02-28 | GSE197259 | GEO
| S-EPMC7816136 | biostudies-literature
2020-10-01 | GSE154998 | GEO
| S-EPMC6986561 | biostudies-literature