Unknown

Dataset Information

0

Solvent extraction and gas chromatography-mass spectrometric determination of probable carcinogen 1,4-dioxane in cosmetic products.


ABSTRACT: In the present work, a method based on solvent extraction and gas chromatography-mass spectrometry (GC-MS) has been validated for the determination of 1,4-dioxane in cosmetics. Various solvents including ethyl acetate, hexane, methanol, dichloromethane and acetone have been used for the extraction of 1,4-dioxane, among them the ethyl acetate was found to be the most efficient extracting solvent. This method has offered excellent quality parameters for instance linearity (R2?>?0.9991), limit of detection (LOD, 0.00065-0.00091?µg/mL), limit of quantification (LOQ, 0.00217-0.00304?µg/mL) and, precision intra-day (1.65-2.60%, n?=?5) and inter-day (0.16-0.32%, n?=?5) in terms of relative standard deviation (RSD%). A total of thirty-nine cosmetic samples of different brands and origin have been studied. Among them, the 1,4-dioxane was found in twenty-three samples (FB1-FB7, MC1-MC4, MC6-MC8, HS3, HS5, BL1-BL3, BL5 and PLD1-PLD3) at the levels between 0.15?µg/mL and 9.92?µg/mL, whereas in sixteen samples (MC5, HS1, HS2, SG1-SG5, BL4 and HP1- HP6) was found to be not detected. The recovery values were achieved between 93% and 99% in both low and high level of spiked samples. In comparison to the traditional analytical techniques, the proposed method was found to be very sensitive and cost-effective for the routine analysis of 1,4-dioxane at low concentration in cosmetics.

SUBMITTER: Alsohaimi IH 

PROVIDER: S-EPMC7090059 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Solvent extraction and gas chromatography-mass spectrometric determination of probable carcinogen 1,4-dioxane in cosmetic products.

Alsohaimi Ibrahim Hotan IH   Khan Mohammad Rizwan MR   Ali Hazim Mohammed HM   Azam Mohammad M   Alammari Ahmed Moid AM  

Scientific reports 20200323 1


In the present work, a method based on solvent extraction and gas chromatography-mass spectrometry (GC-MS) has been validated for the determination of 1,4-dioxane in cosmetics. Various solvents including ethyl acetate, hexane, methanol, dichloromethane and acetone have been used for the extraction of 1,4-dioxane, among them the ethyl acetate was found to be the most efficient extracting solvent. This method has offered excellent quality parameters for instance linearity (R<sup>2</sup> > 0.9991),  ...[more]

Similar Datasets

| S-EPMC8742357 | biostudies-literature
| S-EPMC2961860 | biostudies-other
| S-EPMC2983364 | biostudies-other
| PRJNA382826 | ENA
| PRJNA382825 | ENA
2021-01-25 | GSE158087 | GEO
| S-EPMC2979119 | biostudies-literature
| S-EPMC3435686 | biostudies-literature
2018-05-01 | GSE97758 | GEO