Unknown

Dataset Information

0

Epidural bolus versus continuous epidural infusion analgesia on optic nerve sheath diameter in paediatric patients: A prospective, double-blind, randomised trial.


ABSTRACT: The use of programmed intermittent epidural bolus for postoperative analgesia may have greater analgesic efficacy than continuous epidural infusion. However, the rapid delivery speed used with an epidural bolus is more likely to increase intracranial pressure. We compared the effects of lumbar epidural bolus versus continuous infusion epidural analgesia on intracranial pressure in children using optic nerve sheath diameter as a marker. We randomly assigned 40 paediatric patients to bolus or infusion groups. Epidural analgesia (0.15% ropivacaine 0.3?ml·kg-1) was administered via bolus or infusion. Ultrasonography was used to measure the optic nerve sheath diameter before (T0), at 3?min (T1), 10?min (T2), and 70?min (T3) after starting the pump. There were statistically significant between-group differences in optic nerve sheath diameter over time (PGroup x Time?=?0.045). From T0-T3, the area under the curve values were similar between the two groups. Although there were differences in the patterns of optic nerve sheath diameter change according to the delivery mode, the use of lumbar epidural bolus did not increase the risk of intracranial pressure increase over that of continuous infusion. Further research is needed to investigate intracranial pressure changes after continuous application of each delivery mode.

SUBMITTER: Lee B 

PROVIDER: S-EPMC7096447 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Epidural bolus versus continuous epidural infusion analgesia on optic nerve sheath diameter in paediatric patients: A prospective, double-blind, randomised trial.

Lee Bora B   Lee Jae Hoon JH   Kim Min-Soo MS   Kim Seon Ju SJ   Song Jeehyun J   Kim Do-Hyeong DH   Choi Yong Seon YS  

Scientific reports 20200325 1


The use of programmed intermittent epidural bolus for postoperative analgesia may have greater analgesic efficacy than continuous epidural infusion. However, the rapid delivery speed used with an epidural bolus is more likely to increase intracranial pressure. We compared the effects of lumbar epidural bolus versus continuous infusion epidural analgesia on intracranial pressure in children using optic nerve sheath diameter as a marker. We randomly assigned 40 paediatric patients to bolus or infu  ...[more]

Similar Datasets

| S-EPMC4362123 | biostudies-literature
| S-EPMC6999916 | biostudies-literature
| S-EPMC8613366 | biostudies-literature
| S-EPMC8027451 | biostudies-literature
| S-EPMC6208106 | biostudies-literature
| S-EPMC6384894 | biostudies-other
| S-EPMC7579642 | biostudies-literature
| S-EPMC7292420 | biostudies-literature
| S-EPMC7218034 | biostudies-literature
| S-EPMC8138150 | biostudies-literature