Unknown

Dataset Information

0

Agreement of stall-side and laboratory major crossmatch tests with the reference standard method in horses.


ABSTRACT:

Background

Crossmatching is used to prevent life-threatening transfusion reactions in horses. Laboratory methods are laborious and technically challenging, which is impractical during emergencies.

Hypothesis/objectives

Evaluate agreement between a stall-side crossmatch kit (KIT) and a laboratory method (LAB) in horses with known and unknown blood types.

Animals

Twenty-four blood-typed and alloantibody-screened healthy adult horses (Aim 1) and 156 adult horses of unknown blood type (Aim 2).

Methods

Prospective, blinded study. Expected positive (n = 35) and negative (n = 36) crossmatches among 24 antibody and blood-typed horses were used to determine sensitivity and specificity of KIT and LAB against the reference method. Agreement in 156 untyped horses was evaluated by reciprocal crossmatch (n = 156).

Results

Sensitivity (95% confidence interval [CI]) for LAB and KIT compared with expected reactions was 77.1% (59.9%-90.0%) and 91.4% (77.0%-98.2%), and specificity 77.8% (60.9%-89.9%) and 73.5% (55.6%-87.1%), respectively. The KIT was 100% sensitive for Aa reactions; LAB was 100% sensitive for Qab; and both were 100% sensitive for Ca. Cohen's ? agreement for LAB and KIT with expected positive and negative reactions (n = 71) was moderate (0.55 [0.36-0.74]) and substantial (0.65 [0.47-0.82]), respectively. Agreement was fair comparing LAB with KIT in Aim 1 (0.30 [0.08-0.52]) and in untyped horses in Aim 2 (0.26 [0.11-0.41]).

Conclusions and clinical importance

Agreement between KIT and LAB with expected reactions was blood type dependent. Performance of both methods depends on blood type prevalence.

SUBMITTER: Fenn MS 

PROVIDER: S-EPMC7096648 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Agreement of stall-side and laboratory major crossmatch tests with the reference standard method in horses.

Fenn Melissa S MS   Bortsie-Aryee Araba D AD   Perkins Gillian A GA   Mann Sabine S   Tomlinson Joy E JE   Wood Emma M EM   Mix Susan E SE   Stokol Tracy T  

Journal of veterinary internal medicine 20200204 2


<h4>Background</h4>Crossmatching is used to prevent life-threatening transfusion reactions in horses. Laboratory methods are laborious and technically challenging, which is impractical during emergencies.<h4>Hypothesis/objectives</h4>Evaluate agreement between a stall-side crossmatch kit (KIT) and a laboratory method (LAB) in horses with known and unknown blood types.<h4>Animals</h4>Twenty-four blood-typed and alloantibody-screened healthy adult horses (Aim 1) and 156 adult horses of unknown blo  ...[more]

Similar Datasets

| S-EPMC8404742 | biostudies-literature
| S-EPMC11307920 | biostudies-literature
| S-EPMC2813393 | biostudies-literature
| S-EPMC3530612 | biostudies-literature
| S-EPMC9867561 | biostudies-literature
| S-EPMC5108425 | biostudies-literature
| S-EPMC7591287 | biostudies-literature
| S-EPMC10652431 | biostudies-literature
| S-EPMC6733640 | biostudies-literature
| S-EPMC6148986 | biostudies-literature