Unknown

Dataset Information

0

Many-isocenter optimization for robotic radiotherapy.


ABSTRACT: Despite significant dosimetric gains, clinical implementation of the 4? non-coplanar radiotherapy on the widely available C-arm gantry system is hindered by limited clearance, and the need to perform complex coordinated gantry and couch motion. A robotic radiotherapy platform would be conducive to such treatment but a new conflict between field size and MLC modulation resolution needs to be managed for versatile applications. This study investigates the dosimetry and delivery efficiency of purposefully creating many isocenters to achieve simultaneously high MLC modulation resolution and large tumor coverage. An integrated optimization framework was proposed for simultaneous beam orientation optimization (BOO), isocenter selection, and fluence map optimization (FMO). The framework includes a least-square dose fidelity objective, a total variation term for regularizing the fluence smoothness, and a group sparsity term for beam selection. A minimal number of isocenters were identified for efficient target coverage. Colliding beams excluded, high-resolution small-field 4? intensity-modulated radiotherapy (IMRT) treatment plans with 50?cm source-to-isocenter distance (SID-50) on 10 Head and Neck (H&N) cancer patients were compared with low-resolution large-field plans with 100?cm SID (SID-100). With the same or better target coverage, the average reduction of [Dmean, Dmax] of 20-beam SID-50 plans from 20-beam SID-100 plans were [2.09 Gy, 1.19 Gy] for organs at risk (OARs) overall, [3.05 Gy, 0.04 Gy] for parotid gland, [3.62 Gy, 5.19 Gy] for larynx, and [3.27 Gy, 1.10 Gy] for mandible. R50 and integral dose were reduced by 5.3% and 9.6%, respectively. Wilcoxon signed-rank test showed significant difference (p???

SUBMITTER: Lyu Q 

PROVIDER: S-EPMC7100370 | biostudies-literature | 2020 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Many-isocenter optimization for robotic radiotherapy.

Lyu Qihui Q   Neph Ryan R   Yu Victoria Y VY   Ruan Dan D   Boucher Salime S   Sheng Ke K  

Physics in medicine and biology 20200210 4


Despite significant dosimetric gains, clinical implementation of the 4π non-coplanar radiotherapy on the widely available C-arm gantry system is hindered by limited clearance, and the need to perform complex coordinated gantry and couch motion. A robotic radiotherapy platform would be conducive to such treatment but a new conflict between field size and MLC modulation resolution needs to be managed for versatile applications. This study investigates the dosimetry and delivery efficiency of purpo  ...[more]

Similar Datasets

| S-EPMC9205812 | biostudies-literature
| S-EPMC5714544 | biostudies-literature
| S-EPMC11333576 | biostudies-literature
| S-EPMC9326239 | biostudies-literature
| S-EPMC8457110 | biostudies-literature
| S-EPMC7807558 | biostudies-literature
| S-EPMC8215813 | biostudies-literature
| S-EPMC7063896 | biostudies-literature
| S-EPMC8292055 | biostudies-literature
| S-EPMC6084493 | biostudies-literature