Unknown

Dataset Information

0

Evaluation of new Corvis ST parameters in normal, Post-LASIK, Post-LASIK keratectasia and keratoconus eyes.


ABSTRACT: The aim of this study was to evaluate the distribution of new Corneal Visualisation Scheimpflug Technology (Corvis ST) parameters in normal, Post-laser in situ keratomileusis (LASIK), Post-LASIK keratectasia (KE) and keratoconus (KC) eyes, and explore the diagnostic ability of these parameters in distinguishing KE from LASIK eyes. Twenty-three normal eyes, 23 LASIK eyes, 23 KE eyes and 23 KC eyes were recruited in this study. The following new Corvis ST parameters were measured: Max Inverse Radius, deformation amplitude (DA) Ratio Max [2?mm], Pachy Slope, DA Ratio Max [1?mm], Ambrosio's relational thickness horizontal (ARTh), Integrated Radius, stiffness parameter at first applanation (SP-A1) and Corvis biomechanical index (CBI). The general linear model, linear regression model, relation analysis and receiver operating characteristic (ROC) curve were performed. The Max Inverse Radius, DA Ratio Max [2?mm], Pachy Slope, DA Ratio Max [1?mm], Integrated Radius and CBI in LASIK eyes, KE eyes and KC eyes were higher than in normal eyes, while the ARTh and SP-A1 parameters were lower than in normal eyes. The KE eyes had higher Max Inverse Radius, DA Ratio Max [2?mm], Pachy Slope, DA Ratio Max [1?mm], Integrated Radius, and lower SP-A1 value than LASIK eyes (all P?

SUBMITTER: Yang K 

PROVIDER: S-EPMC7105482 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of new Corvis ST parameters in normal, Post-LASIK, Post-LASIK keratectasia and keratoconus eyes.

Yang Kaili K   Xu Liyan L   Fan Qi Q   Gu Yuwei Y   Song Peng P   Zhang Bo B   Zhao Dongqing D   Pang Chenjiu C   Ren Shengwei S  

Scientific reports 20200330 1


The aim of this study was to evaluate the distribution of new Corneal Visualisation Scheimpflug Technology (Corvis ST) parameters in normal, Post-laser in situ keratomileusis (LASIK), Post-LASIK keratectasia (KE) and keratoconus (KC) eyes, and explore the diagnostic ability of these parameters in distinguishing KE from LASIK eyes. Twenty-three normal eyes, 23 LASIK eyes, 23 KE eyes and 23 KC eyes were recruited in this study. The following new Corvis ST parameters were measured: Max Inverse Radi  ...[more]

Similar Datasets

| S-EPMC6814725 | biostudies-literature
| S-EPMC5006993 | biostudies-literature
| S-EPMC4038409 | biostudies-literature
| S-EPMC7510959 | biostudies-literature
| S-EPMC4618943 | biostudies-literature
| S-EPMC9436129 | biostudies-literature
| S-EPMC9248133 | biostudies-literature
| S-EPMC7125474 | biostudies-literature
| S-EPMC4123636 | biostudies-literature
| S-EPMC5357464 | biostudies-other