Relationship Between Electrical Instability and Pumping Performance During Ventricular Tachyarrhythmia: Computational Study.


ABSTRACT: There are representative electrical parameters for understanding the mechanism of reentrant waves in studies on tachyarrhythmia, namely the action potential duration (APD), dominant frequency, phase singularity, and filament. However, there are no studies that have directly identified the correlation between these electrophysiological parameters and cardiac contractility. Therefore, we have identified individual and integrative correlations between these electrical phenomena and contractility during tachyarrhythmia by deriving regression equations and also investigated the electrophysiological parameters affecting cardiac contractility during tachyarrhythmia. We simulated ventricular tachyarrhythmia with 48 types of electrical patterns by applying four reentry generation methods and changing the electrical conductivity of the potassium channel, which has the greatest effect on ventricular tissue. The mechanical responses reflecting electrical complexity were obtained through deterministic simulations of excitation-contraction coupling. We used the stroke volume and amplitude of myocardial tension (ampTens) as the variables representing contractility. We derived stochastic models through single- and multivariable regression analyses to identify the electrical parameters affecting contractility during tachyarrhythmia. In single-variable regression analysis, the APD, dominant frequency, and filament, excluding phase singularity, have statistically significant correlations with the stroke volume and ampTens. Among them, the APD has the maximum influence on these two mechanical parameters (standard beta coefficient: 0.859 for stroke volume, 0.930 for ampTens). The stochastic model using all four electrical parameters fails to accurately predict contractility owing to the multicollinearity between the APD and dominant frequency. We have rederived the multi-variable stochastic model using three electrical parameters without the APD. The filament has the greatest effect on the stroke volume stochastically (standard beta coefficient: 0.853 and 0.752). The dominant frequency has the greatest effect on ampTens statistically (standard beta coefficient: -0.813). We conclude that among the electrical parameters, the APD has the highest individual influence on mechanical contraction, and the filament has the highest integrative influence in both statistical terms.

SUBMITTER: Jeong DU 

PROVIDER: S-EPMC7105731 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Relationship Between Electrical Instability and Pumping Performance During Ventricular Tachyarrhythmia: Computational Study.

Jeong Da Un DU   Lim Ki Moo KM  

Frontiers in physiology 20200324


There are representative electrical parameters for understanding the mechanism of reentrant waves in studies on tachyarrhythmia, namely the action potential duration (APD), dominant frequency, phase singularity, and filament. However, there are no studies that have directly identified the correlation between these electrophysiological parameters and cardiac contractility. Therefore, we have identified individual and integrative correlations between these electrical phenomena and contractility du  ...[more]

Similar Datasets

| S-EPMC7732497 | biostudies-literature
| S-EPMC9935011 | biostudies-literature
| S-EPMC6052854 | biostudies-literature
| S-EPMC8209189 | biostudies-literature
| S-EPMC11317526 | biostudies-literature
| S-EPMC6080549 | biostudies-literature
| S-EPMC4451795 | biostudies-other
| S-EPMC8425921 | biostudies-literature
| S-EPMC9473303 | biostudies-literature
| S-EPMC4972162 | biostudies-literature