First international proficiency study on West Nile virus molecular detection.


ABSTRACT: BACKGROUND:West Nile virus (WNV) molecular detection is being conducted by a growing number of laboratories, but the degree of proficiency may vary between them. External quality control is needed. METHODS:We have conducted an international quality assurance study on WNV molecular detection. Participating laboratories tested noninfectious samples inactivated by heat and gamma irradiation. Participants received 7 coded lyophilized samples containing WNV of genetic lineages 1a, 1b, and 2 at 2600 to 18 000 000 RNA copies/mL, 3 samples containing heterologous flaviviruses, and 2 negative samples. RESULTS:Thirty laboratories participated. The average laboratory achieved 50% detection probability from 7762 copies/mL onward (probit analysis; 95% CI = 1174-24547 copies/mL). Lineages 1a and 1b were detected with equal efficiencies, but the lineage 2 strain (Ug37) was detected at significantly lower rates. Only 27% of participants were able to detect the 6 samples containing > or =1.8 x 10(4) copies/mL. Three laboratories generated false-positive results in negative samples. Six of 30 laboratories reported correct strain identification in 3 samples containing non-WNV flaviviruses. We observed a significant positive correlation between the capability of detecting non-WNV flaviviruses and detecting WNV lineage 2. CONCLUSIONS:Most participants showed good performance in detecting lineage 1 WNV, the predominant virus in the Northern Hemisphere. The inability of some laboratories to detect even highly concentrated lineage 2 WNV downgraded the overall outcome. The lineage 2 material received through this study will provide laboratories with the necessary template for improving their assays. Such material is otherwise hard to obtain.

SUBMITTER: Niedrig M 

PROVIDER: S-EPMC7108183 | biostudies-literature | 2006 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

First international proficiency study on West Nile virus molecular detection.

Niedrig Matthias M   Linke Sonja S   Zeller Herve H   Drosten Christian C  

Clinical chemistry 20060803 10


<h4>Background</h4>West Nile virus (WNV) molecular detection is being conducted by a growing number of laboratories, but the degree of proficiency may vary between them. External quality control is needed.<h4>Methods</h4>We have conducted an international quality assurance study on WNV molecular detection. Participating laboratories tested noninfectious samples inactivated by heat and gamma irradiation. Participants received 7 coded lyophilized samples containing WNV of genetic lineages 1a, 1b,  ...[more]

Similar Datasets

| S-EPMC3636139 | biostudies-other
| S-EPMC5204039 | biostudies-literature
| S-EPMC3320471 | biostudies-literature
| S-EPMC7996184 | biostudies-literature
| S-EPMC6343470 | biostudies-literature
| PRJNA1096139 | ENA
| PRJNA1168961 | ENA
| PRJEB80643 | ENA
| PRJNA655813 | ENA
| PRJNA1035118 | ENA