Unknown

Dataset Information

0

Diagnostic reverse-transcription polymerase chain reaction kit for filoviruses based on the strain collections of all European biosafety level 4 laboratories.


ABSTRACT: A network of European biosafety level 4 laboratories has designed the first industry-standard molecular assay for all filoviruses species, based on the strain collections of all participants. It uses 5 optimized L gene primers and 3 probes, as well as an internal control with a separate detection probe. Detection limits (probit analysis, 95% detection chance) were as follows: Zaire ebolavirus, 487 copies/mL of plasma; Sudan ebolavirus Maleo, 586 copies/mL; Sudan ebolavirus Gulu, 1128 copies/mL; Cote d'Ivoire ebolavirus, 537 copies/mL; Reston ebolavirus, 4546 copies/mL; Lake Victoria marburgvirus Musoke, 860 copies/mL; and Lake Victoria marburgvirus Ravn, 1551 copies/mL. The assay facilitates reliable detection or exclusion screening of filovirus infections.

SUBMITTER: Panning M 

PROVIDER: S-EPMC7109892 | biostudies-literature | 2007 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Diagnostic reverse-transcription polymerase chain reaction kit for filoviruses based on the strain collections of all European biosafety level 4 laboratories.

Panning Marcus M   Laue Thomas T   Olschlager Stephan S   Eickmann Markus M   Becker Stephan S   Raith Sabine S   Courbot Marie-Claude Georges MC   Nilsson Mikael M   Gopal Robin R   Lundkvist Ake A   di Caro Antonino A   Brown David D   Meyer Hermann H   Lloyd Graham G   Kummerer Beate M BM   Gunther Stephan S   Drosten Christian C  

The Journal of infectious diseases 20071101


A network of European biosafety level 4 laboratories has designed the first industry-standard molecular assay for all filoviruses species, based on the strain collections of all participants. It uses 5 optimized L gene primers and 3 probes, as well as an internal control with a separate detection probe. Detection limits (probit analysis, 95% detection chance) were as follows: Zaire ebolavirus, 487 copies/mL of plasma; Sudan ebolavirus Maleo, 586 copies/mL; Sudan ebolavirus Gulu, 1128 copies/mL;  ...[more]

Similar Datasets

| S-EPMC6003926 | biostudies-literature
| S-EPMC6101963 | biostudies-literature
| S-EPMC7121124 | biostudies-literature
| S-EPMC7856914 | biostudies-literature
| S-EPMC6281642 | biostudies-literature
| S-EPMC3322901 | biostudies-literature
| S-EPMC7126732 | biostudies-literature
| S-EPMC4909037 | biostudies-literature
| S-EPMC7119510 | biostudies-literature
| S-EPMC4994868 | biostudies-literature