Unknown

Dataset Information

0

Outcome of mechanical circulatory support at the University Medical Centre Utrecht.


ABSTRACT: BACKGROUND:The prevalence of heart failure (HF) is increasing substantially and, despite improvements in medical therapy, HF still carries a poor prognosis. Mechanical circulatory support (MCS) by a continuous-flow left ventricular assist device (cf-LVAD) improves survival and quality of life in selected patients. This holds especially for the short-term outcome, but experience regarding long-term outcome is growing as the waiting time for heart transplantation is increasing due to the shortage of donor hearts. Here we present our results from the University Medical Centre Utrecht. METHODS:Data of all patients with a cf-LVAD implant between March 2006 and January 2018 were collected. The primary outcome was survival. Secondary outcomes included adverse events defined according to the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) definitions, described per patient year. RESULTS:A total of 268 patients (69% male, mean age 50?±?13 years) received a cf-LVAD. After a median follow-up of 542 (interquartile range 205-1044) days, heart transplantation had been performed in 82 (31%) patients, the cf-LVAD had been explanted in 8 (3%) and 71 (26%) had died. Survival at 1, 3 and 5 years was 83%, 72% and 57%, respectively, with heart transplantation, cf-LVAD explantation or death as the end-point. Death was most often caused by neurological complications (31%) or infection (20%). Major bleeding occurred 0.51 times and stroke 0.15 times per patient year. CONCLUSION:Not only short-term results but also 5?year survival after cf-LVAD support demonstrate that MCS is a promising therapy as an extended bridge to heart transplantation. However, the incidence of several major complications still has to be addressed.

SUBMITTER: Felix SEA 

PROVIDER: S-EPMC7113343 | biostudies-literature | 2020 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Outcome of mechanical circulatory support at the University Medical Centre Utrecht.

Felix S E A SEA   Ramjankhan F Z FZ   Buijsrogge M P MP   Jacob K A KA   Asselbergs F W FW   Oerlemans M I F MIF   Kirkels J H JH   van Laake L W LW   Oppelaar A M C AMC   Suyker W J L WJL   de Jonge N N  

Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation 20200401 4


<h4>Background</h4>The prevalence of heart failure (HF) is increasing substantially and, despite improvements in medical therapy, HF still carries a poor prognosis. Mechanical circulatory support (MCS) by a continuous-flow left ventricular assist device (cf-LVAD) improves survival and quality of life in selected patients. This holds especially for the short-term outcome, but experience regarding long-term outcome is growing as the waiting time for heart transplantation is increasing due to the s  ...[more]

Similar Datasets

| S-EPMC8271054 | biostudies-literature
| S-EPMC4703699 | biostudies-literature
| S-EPMC7538495 | biostudies-literature
| S-EPMC10375086 | biostudies-literature
| S-EPMC4191250 | biostudies-literature
| S-EPMC7111303 | biostudies-literature
| S-EPMC7396248 | biostudies-literature
| S-EPMC9524665 | biostudies-literature
| S-EPMC10641702 | biostudies-literature
| S-EPMC5063158 | biostudies-literature