Unknown

Dataset Information

0

Suture-Based Debris Behavior in the Draining Lymph Nodes of a Porcine Knee: A Study of Silicone, Polyethylene and Carbon.


ABSTRACT: Purpose:To determine whether debris from a silicone core suture has an observable intra-articular or extra-articular impact or can be shown to migrate into the lymphatic system. Methods:Using a porcine stifle joint model, 2 study groups were created: 1 group used silicone-suture particles created by rupturing hand-tied knots of a nonabsorbable suture with an outer sheath of ultrahigh molecular-weight polyethylene, an inner polyester sheath and a medical-grade silicone/sodium chloride-filled core. The second group used a mixture of 3 vitreous carbon particles sizes. Twelve Yorkshire pigs were randomly assigned to each group. Only 1 type of study particle was used in a single animal to avoid cross-contamination. Half of the study materials were placed by arthrotomy into the joint and, after capsular closure, the remaining half were placed on the joint capsule before skin closure. Six weeks postimplantation, the stifle joints and regional lymph nodes were examined macroscopically and microscopically. The extracapsular and intra-articular tissue and the lymph nodes were examined. Results:Macroscopically, none of the 12 silicone-suture particle group limbs had abnormal macroscopic observations. Of the 12 limbs in the carbon particle group, 8 demonstrated discoloration in the extracapsular, intra-articular and lymph node tissues; 6 limbs demonstrated joint discoloration (extracapsular and intra-articular). The silicone-suture particle group showed lymph node inflammation in 25% of the iliac lymph nodes and 42% of the inguinal lymph nodes but none in the popliteal lymph nodes. In the carbon particle group, 100% of the iliac lymph nodes, 75% of the inguinal lymph nodes and 8% of the popliteal nodes showed inflammation. No silicone-suture debris migration was observed microscopically. Visible carbon particle migration was present in 100% of the iliac lymph nodes and in 50% of the inguinal lymph nodes but in none (0) of the popliteal lymph nodes. The carbon particle group also showed inflammation in these areas. Conclusions:Carbon particles in the porcine knee migrated into the lymph nodes (iliac 100%; inguinal 50%, popliteal 0); gross discoloration was observed in 8 of 12 specimens. Silicone-suture particles could not be found in the lymph nodes, and no macroscopic joint damage was observed. Clinical Relevance:The clinical use of a suture containing a silicone/salt central core is common, and the porcine lymphatic model suggests that this type of suture material does not result in clinically significant silicone particulates.

SUBMITTER: Barber FA 

PROVIDER: S-EPMC7120811 | biostudies-literature | 2019 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Suture-Based Debris Behavior in the Draining Lymph Nodes of a Porcine Knee: A Study of Silicone, Polyethylene and Carbon.

Barber F Alan FA   Spenciner David B DB   Zani Brett G BG   Melidone Raffaele R  

Arthroscopy, sports medicine, and rehabilitation 20191127 2


<h4>Purpose</h4>To determine whether debris from a silicone core suture has an observable intra-articular or extra-articular impact or can be shown to migrate into the lymphatic system.<h4>Methods</h4>Using a porcine stifle joint model, 2 study groups were created: 1 group used silicone-suture particles created by rupturing hand-tied knots of a nonabsorbable suture with an outer sheath of ultrahigh molecular-weight polyethylene, an inner polyester sheath and a medical-grade silicone/sodium chlor  ...[more]

Similar Datasets

| S-EPMC5469692 | biostudies-literature
| S-EPMC6315107 | biostudies-literature
| S-EPMC2928294 | biostudies-literature
| S-EPMC9271705 | biostudies-literature
| S-EPMC6668680 | biostudies-literature
| S-EPMC7081353 | biostudies-literature
| S-EPMC6328025 | biostudies-literature
| S-EPMC4684422 | biostudies-literature
| S-EPMC7935407 | biostudies-literature
| S-EPMC5149544 | biostudies-literature