Unknown

Dataset Information

0

Mobile App for Pre- and Intraoperative Assessment of Astigmatism Correction with Toric Intraocular Lenses in Cataract Surgery.


ABSTRACT: Purpose:To develop a mobile app that allows capturing and editing of photographs, performs image transposition and projection of a protractor with 360° axis markings, and permits accurate visualization of programmed alignment for the positioning of toric intraocular lenses (IOLs). Methods:In this prospective case series study, a codesign methodology was chosen to develop the Eye Axis Check application. After app development, measurements were obtained and comparisons were made between manual marks and toric IOL alignment without and with the app in 30 eyes that had undergone cataract surgery with toric IOLs. The mobile app was made available to 15 ophthalmic surgeons in different cities to assess its usability. Results:The users approved the developed application for its ease of use and utility. The mean difference between the markings made manually and those made with the app was 1° (±2°; range: 0°-5°), and the mean difference between the IOL position and the assessment made by the app was 3° (±3°; range: 0°-12°). Upon comparison of the agreement between the app measurements and the manual measurements for the IOL angle, no significant differences were found, and an excellent concordance (0.997) and a strong positive linear correlation (0.995) were observed. Conclusion:A mobile app for preoperative planning and intraoperative toric IOL alignment was developed and revealed to be useful and easy to use.

SUBMITTER: Dias FAF 

PROVIDER: S-EPMC7125467 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Mobile App for Pre- and Intraoperative Assessment of Astigmatism Correction with Toric Intraocular Lenses in Cataract Surgery.

Dias Francisco Aecio Fernandes FAF   Dias Vinicius Jose Fernandes VJF   Dutra Barbara de Araujo Lima BAL   Marques Anna Christina Siqueira ACS   Marçal Edgar E   Lucena Abrahao da Rocha ADR   Crispim Ribeiro Joao J  

Journal of ophthalmology 20200315


<h4>Purpose</h4>To develop a mobile app that allows capturing and editing of photographs, performs image transposition and projection of a protractor with 360° axis markings, and permits accurate visualization of programmed alignment for the positioning of toric intraocular lenses (IOLs).<h4>Methods</h4>In this prospective case series study, a codesign methodology was chosen to develop the Eye Axis Check application. After app development, measurements were obtained and comparisons were made bet  ...[more]

Similar Datasets

| S-EPMC8786790 | biostudies-literature
| S-EPMC7787088 | biostudies-literature
| S-EPMC6916141 | biostudies-literature
| S-EPMC8302686 | biostudies-literature
| S-EPMC6463930 | biostudies-literature