Unknown

Dataset Information

0

A proof-of-principle bite force study using two experimental test denture adhesives and a currently marketed denture adhesive.


ABSTRACT: OBJECTIVES:This proof-of-principle, single-center, randomized, examiner-blind, crossover study compared two experimental polyvinyl acetate (PVA)-based denture adhesives (Test Adhesives 1 and 2) with a marketed reference polymethyl vinyl ether/maleic anhydride (PMV/MA)-based adhesive and no adhesive using incisal bite force area over baseline over 12 hr (AOB0-12 ) in participants with an at least moderately well-fitting complete maxillary denture. Previous in vitro studies suggested the experimental denture adhesives provided superior performance. MATERIALS AND METHODS:Participants were randomized to a treatment sequence such that each received each treatment once. Prior to treatment application (baseline) and at 0.5, 1, 3, 6, 9, and 12 hr following the application, participants bit on a force transducer until their maxillary denture dislodged. Between-treatment differences in AOB0-12 were analyzed using analysis of covariance. For study validity, the reference adhesive was compared with no adhesive. Participants were asked to rate sensory experiences and ease of denture removal. RESULTS:Twenty-three participants were included in the modified intent-to-treat population. Although Test Adhesives 1 and 2 had a higher mean AOB0-12 than no adhesive, differences were not statistically significant. No statistically significant difference was also found between the reference adhesive and no adhesive; hence, study validity was not attained. Participants did not report any clear differences between the test or reference adhesives in terms of taste or feel; however, dentures were easier to remove with the test adhesives versus reference. No treatment-related adverse events were reported. CONCLUSION:Neither the experimental PVA-based denture adhesives nor the PMV/MA-based reference product demonstrated a statistically significant difference in incisal bite force AOB0-12 compared with no adhesive. The reasons for these unexpected results is unclear; they suggest that findings of in vitro tests for denture adhesive performance are not always translated to in vivo performance (Clinicaltrials.gov: NCT02937870).

SUBMITTER: Atassi M 

PROVIDER: S-EPMC7133722 | biostudies-literature | 2020 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

A proof-of-principle bite force study using two experimental test denture adhesives and a currently marketed denture adhesive.

Atassi Mounir M   Ling Martin R MR   Oneglia Kathy K   Dilauro Thomas S TS  

Clinical and experimental dental research 20200206 2


<h4>Objectives</h4>This proof-of-principle, single-center, randomized, examiner-blind, crossover study compared two experimental polyvinyl acetate (PVA)-based denture adhesives (Test Adhesives 1 and 2) with a marketed reference polymethyl vinyl ether/maleic anhydride (PMV/MA)-based adhesive and no adhesive using incisal bite force area over baseline over 12 hr (AOB<sub>0-12</sub> ) in participants with an at least moderately well-fitting complete maxillary denture. Previous in vitro studies sugg  ...[more]

Similar Datasets

| S-EPMC6585581 | biostudies-literature
| S-EPMC7328800 | biostudies-literature
2006-10-23 | GSE5721 | GEO
2010-05-26 | E-GEOD-10761 | biostudies-arrayexpress
2010-04-09 | GSE20873 | GEO
2008-03-08 | GSE10761 | GEO
2008-04-12 | E-GEOD-11075 | biostudies-arrayexpress
2016-06-15 | E-GEOD-83353 | biostudies-arrayexpress
| S-EPMC4260937 | biostudies-literature
| S-EPMC4297017 | biostudies-other