Unknown

Dataset Information

0

The Dynamics of Respiratory Microbiota during Mechanical Ventilation in Patients with Pneumonia.


ABSTRACT: Bacterial pneumonia is a major cause of mechanical ventilation in intensive care units. We hypothesized that the presence of particular microbiota in endotracheal tube aspirates during the course of intubation was associated with clinical outcomes such as extubation failure or 28-day mortality. Sixty mechanically ventilated ICU (intensive care unit) patients (41 patients with pneumonia and 19 patients without pneumonia) were included, and tracheal aspirates were obtained on days 1, 3, and 7. Gene sequencing of 16S rRNA was used to measure the composition of the respiratory microbiome. A total of 216 endotracheal aspirates were obtained from 60 patients. A total of 22 patients were successfully extubatedwithin3 weeks, and 12 patients died within 28days. Microbiota profiles differed significantly between the pneumonia group and the non-pneumonia group (Adonis, p < 0.01). While ? diversity (Shannon index) significantly decreased between day 1 and day 7 in the successful extubation group, it did not decrease in the failed extubation group among intubated patients with pneumonia. There was a significant difference in the change of ?diversity between the successful extubation group and the failed extubation group for Bray-Curtis distances (p < 0.001). At the genus level, Rothia, Streptococcus, and Prevotella correlated with the change of ? diversity. A low relative abundance of Streptococci at the time of intubation was strongly associated with 28-day mortality. The dynamics of respiratory microbiome were associated with clinical outcomes such as extubation failure and mortality. Further large prospective studies are needed to test the predictive value of endotracheal aspirates in intubated patients.

SUBMITTER: Woo S 

PROVIDER: S-EPMC7141134 | biostudies-literature | 2020 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

The Dynamics of Respiratory Microbiota during Mechanical Ventilation in Patients with Pneumonia.

Woo Seongji S   Park So-Yeong SY   Kim Youngmi Y   Jeon Jin Pyeong JP   Lee Jae Jun JJ   Hong Ji Young JY  

Journal of clinical medicine 20200227 3


Bacterial pneumonia is a major cause of mechanical ventilation in intensive care units. We hypothesized that the presence of particular microbiota in endotracheal tube aspirates during the course of intubation was associated with clinical outcomes such as extubation failure or 28-day mortality. Sixty mechanically ventilated ICU (intensive care unit) patients (41 patients with pneumonia and 19 patients without pneumonia) were included, and tracheal aspirates were obtained on days 1, 3, and 7. Gen  ...[more]

Similar Datasets

| S-EPMC6929358 | biostudies-literature
| S-EPMC8012590 | biostudies-literature
| S-EPMC7092676 | biostudies-literature
| S-EPMC7876671 | biostudies-literature
| S-EPMC7126754 | biostudies-literature
| S-EPMC6078986 | biostudies-literature
| S-EPMC5603635 | biostudies-literature
| S-EPMC7092518 | biostudies-literature
| S-EPMC9487769 | biostudies-literature
| S-EPMC7925253 | biostudies-literature