Unknown

Dataset Information

0

Assessment of DCE Utility for PCa Diagnosis Using PI-RADS v2.1: Effects on Diagnostic Accuracy and Reproducibility.


ABSTRACT: The role of dynamic contrast-enhanced-MRI (DCE-MRI) for Prostate Imaging-Reporting and Data System (PI-RADS) scoring is a controversial topic. In this retrospective study, we aimed to measure the added value of DCE-MRI in combination with T2-weighted (T2W) and diffusion-weighted imaging (DWI) using PI-RADS v2.1, in terms of reproducibility and diagnostic accuracy, for detection of prostate cancer (PCa) and clinically significant PCa (CS-PCa, for Gleason Score ? 7). 117 lesions in 111 patients were identified as suspicion by multiparametric MRI (mpMRI) and addressed for biopsy. Three experienced readers independently assessed PI-RADS score, first using biparametric MRI (bpMRI, including DWI and T2W), and then multiparametric MRI (also including DCE). The inter-rater and inter-method agreement (bpMRI- vs. mpMRI-based scores) were assessed by Cohen's kappa (?). Receiver operating characteristics (ROC) analysis was performed to evaluate the diagnostic accuracy for PCa and CS-PCa detection among the two scores. Inter-rater agreement was excellent for the three pairs of readers (? ? 0.83), while the inter-method agreement was good (? ? 0.73). Areas under the ROC curve (AUC) showed similar high-values (0.8 ? AUC ? 0.85). The reproducibility of PI-RADS v2.1 scoring was comparable and high among readers, without relevant differences, depending on the MRI protocol used. The inclusion of DCE did not influence the diagnostic accuracy.

SUBMITTER: Brancato V 

PROVIDER: S-EPMC7151226 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Assessment of DCE Utility for PCa Diagnosis Using PI-RADS v2.1: Effects on Diagnostic Accuracy and Reproducibility.

Brancato Valentina V   Di Costanzo Giuseppe G   Basso Luca L   Tramontano Liberatore L   Puglia Marta M   Ragozzino Alfonso A   Cavaliere And Carlo AC  

Diagnostics (Basel, Switzerland) 20200317 3


The role of dynamic contrast-enhanced-MRI (DCE-MRI) for Prostate Imaging-Reporting and Data System (PI-RADS) scoring is a controversial topic. In this retrospective study, we aimed to measure the added value of DCE-MRI in combination with T2-weighted (T2W) and diffusion-weighted imaging (DWI) using PI-RADS v2.1, in terms of reproducibility and diagnostic accuracy, for detection of prostate cancer (PCa) and clinically significant PCa (CS-PCa, for Gleason Score ≥ 7). 117 lesions in 111 patients we  ...[more]

Similar Datasets

| S-EPMC7925826 | biostudies-literature
| S-EPMC7535021 | biostudies-literature
| S-EPMC6614909 | biostudies-literature
| S-EPMC7934301 | biostudies-literature
| S-EPMC6677282 | biostudies-other
| S-EPMC7069157 | biostudies-literature
| S-EPMC5006735 | biostudies-literature
| S-EPMC8554332 | biostudies-literature
| S-EPMC5464550 | biostudies-literature
| S-EPMC9939143 | biostudies-literature