Voltage Imaging of Cardiac Cells and Tissue Using the Genetically Encoded Voltage Sensor Archon1.


ABSTRACT: Precise measurement of action potentials (APs) is needed to observe electrical activity and cellular communication within cardiac tissue. Voltage-sensitive dyes (VSDs) are traditionally used to measure cardiac APs; however, they require acute chemical addition that prevents chronic imaging. Genetically encoded voltage indicators (GEVIs) enable long-term studies of APs without the need of chemical additions, but current GEVIs used in cardiac tissue exhibit poor kinetics and/or low signal to noise (SNR). Here, we demonstrate the use of Archon1, a recently developed GEVI, in hiPSC-derived cardiomyocytes (CMs). When expressed in CMs, Archon1 demonstrated fast kinetics comparable with patch-clamp electrophysiology and high SNR significantly greater than the VSD Di-8-ANEPPS. Additionally, Archon1 enabled monitoring of APs across multiple cells simultaneously in 3D cardiac tissues. These results highlight Archon1's capability to investigate the electrical activity of CMs in a variety of applications and its potential to probe functionally complex in vitro models, as well as in vivo systems.

SUBMITTER: Shroff SN 

PROVIDER: S-EPMC7160579 | biostudies-literature | 2020 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Voltage Imaging of Cardiac Cells and Tissue Using the Genetically Encoded Voltage Sensor Archon1.

Shroff Sanaya N SN   Das Shoshana L SL   Tseng Hua-An HA   Noueihed Jad J   Fernandez Fernando F   White John A JA   Chen Christopher S CS   Han Xue X  

iScience 20200311 4


Precise measurement of action potentials (APs) is needed to observe electrical activity and cellular communication within cardiac tissue. Voltage-sensitive dyes (VSDs) are traditionally used to measure cardiac APs; however, they require acute chemical addition that prevents chronic imaging. Genetically encoded voltage indicators (GEVIs) enable long-term studies of APs without the need of chemical additions, but current GEVIs used in cardiac tissue exhibit poor kinetics and/or low signal to noise  ...[more]

Similar Datasets

| S-EPMC3715760 | biostudies-other
| S-EPMC5700382 | biostudies-literature
| S-EPMC5584994 | biostudies-literature
| S-EPMC3923221 | biostudies-literature
| S-EPMC6413708 | biostudies-literature
| S-EPMC3126897 | biostudies-literature
| S-EPMC5679667 | biostudies-literature
| S-EPMC4287159 | biostudies-literature
| S-EPMC9917304 | biostudies-literature
| S-EPMC8831244 | biostudies-literature