Unknown

Dataset Information

0

Intraocular pressure reduction in a pigmentary glaucoma model by Goniotome Ab interno trabeculectomy.


ABSTRACT: PURPOSE:To investigate whether microsurgical excision of trabecular meshwork (TM) in an ex vivo pigmentary glaucoma model can normalize the hypertensive phenotype. METHODS:Eight eyes of a porcine pigmentary glaucoma model underwent 90° of microsurgical TM excision with an aspirating dual-blade (Goniotome (G)). 24 hours later, additional 90° of TM were removed. Anterior segments with sham surgeries served as the control (C). Outflow facility and intraocular pressure (IOP) were analyzed. Histology with hematoxylin and eosin (H&E) was obtained. RESULTS:After the first 90° TM excision, IOP was significantly lower in G (10.2±2.4 mmHg, n = 7) than C (20.0±2.0mmHg, n = 8, P<0.01). Outflow facility in G (0.38±0.07 ?l/min/mmHg) was higher than C (0.16±0.02 ?l/min/mmHg, P<0.01). After the second 90° TM excision, IOP in G (6.46±0.81 mmHg, n = 7) was significantly lower than C (20.3±1.7 mmHg, n = 8, P<0.001), while the outflow facility in G (0.50±0.05 ?l/min/mmHg, n = 7) was higher than C (0.16±0.01 ?l/min/mmHg, n = 8, P<0.001). Compared to the first excision, excision of an additional 90° did not change of IOP (P = 0.20) or outflow facility (P = 0.17) further. CONCLUSIONS:Excision of 90° of TM in a pigmentary glaucoma model using an aspirating dual-blade decreased IOP and increased outflow facility.

SUBMITTER: Wang C 

PROVIDER: S-EPMC7162452 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Intraocular pressure reduction in a pigmentary glaucoma model by Goniotome Ab interno trabeculectomy.

Wang Chao C   Dang Yalong Y   Shah Priyal P   Esfandiari Hamed H   Hong Ying Y   Loewen Ralitsa T RT   Waxman Susannah S   Atta Sarah S   Xia Xiaobo X   Loewen Nils A NA  

PloS one 20200416 4


<h4>Purpose</h4>To investigate whether microsurgical excision of trabecular meshwork (TM) in an ex vivo pigmentary glaucoma model can normalize the hypertensive phenotype.<h4>Methods</h4>Eight eyes of a porcine pigmentary glaucoma model underwent 90° of microsurgical TM excision with an aspirating dual-blade (Goniotome (G)). 24 hours later, additional 90° of TM were removed. Anterior segments with sham surgeries served as the control (C). Outflow facility and intraocular pressure (IOP) were anal  ...[more]

Similar Datasets

| S-EPMC5915754 | biostudies-literature
| S-EPMC8348769 | biostudies-literature
| S-EPMC5428488 | biostudies-literature
| S-EPMC8211240 | biostudies-literature
| S-EPMC8163518 | biostudies-literature
| S-EPMC4501175 | biostudies-literature
| S-EPMC8016747 | biostudies-literature
| S-EPMC5627910 | biostudies-literature
| S-EPMC6426190 | biostudies-literature
| S-EPMC5095709 | biostudies-literature