Visualizing the dynamic change of Ocular Response Analyzer waveform using Variational Autoencoder in association with the peripapillary retinal arteries angle.


ABSTRACT: The aim of the current study is to identify possible new Ocular Response Analyzer (ORA) waveform parameters related to changes of retinal structure/deformation, as measured by the peripapillary retinal arteries angle (PRAA), using a generative deep learning method of variational autoencoder (VAE). Fifty-four eyes of 52 subjects were enrolled. The PRAA was calculated from fundus photographs and was used to train a VAE model. By analyzing the ORA waveform reconstructed (noise filtered) using VAE, a novel ORA waveform parameter (Monot1-2), was introduced, representing the change in monotonicity between the first and second applanation peak of the waveform. The variables mostly related to the PRAA were identified from a set of 41 variables including age, axial length (AL), keratometry, ORA corneal hysteresis, ORA corneal resistant factor, 35 well established ORA waveform parameters, and Monot1-2, using a model selection method based on the second-order bias-corrected Akaike information criterion. The optimal model for PRAA was the AL and six ORA waveform parameters, including Monot1-2. This optimal model was significantly better than the model without Monot1-2 (p?=?0.0031, ANOVA). The current study suggested the value of a generative deep learning approach in discovering new useful parameters that may have clinical relevance.

SUBMITTER: Asano S 

PROVIDER: S-EPMC7170838 | biostudies-literature | 2020 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Visualizing the dynamic change of Ocular Response Analyzer waveform using Variational Autoencoder in association with the peripapillary retinal arteries angle.

Asano Shotaro S   Asaoka Ryo R   Yamashita Takehiro T   Aoki Shuichiro S   Matsuura Masato M   Fujino Yuri Y   Murata Hiroshi H   Nakakura Shunsuke S   Nakao Yoshitaka Y   Kiuchi Yoshiaki Y  

Scientific reports 20200420 1


The aim of the current study is to identify possible new Ocular Response Analyzer (ORA) waveform parameters related to changes of retinal structure/deformation, as measured by the peripapillary retinal arteries angle (PRAA), using a generative deep learning method of variational autoencoder (VAE). Fifty-four eyes of 52 subjects were enrolled. The PRAA was calculated from fundus photographs and was used to train a VAE model. By analyzing the ORA waveform reconstructed (noise filtered) using VAE,  ...[more]

Similar Datasets

| S-EPMC6029869 | biostudies-literature
| S-EPMC7450509 | biostudies-literature
| S-EPMC8633506 | biostudies-literature
| S-EPMC4220297 | biostudies-literature
| S-EPMC8456615 | biostudies-literature
| S-EPMC9192707 | biostudies-literature
| S-EPMC6052253 | biostudies-literature
| S-EPMC8485214 | biostudies-literature
| S-EPMC11008089 | biostudies-literature
| S-EPMC9388855 | biostudies-literature