Staging achilles tendinopathy using ultrasound imaging: the development and investigation of a new ultrasound imaging criteria based on the continuum model of tendon pathology.


ABSTRACT: Aim:To develop a standardised ultrasound imaging (USI)-based criteria for the diagnosis of tendinopathy that aligns with the continuum model of tendon pathology. Secondary aims were to assess both the intra-rater and inter-rater reliability of the criteria. Methods:A criteria was developed following a face validity assessment and a total of 31 Achilles tendon ultrasound images were analysed. Intra-rater and inter-rater reliability were assessed for overall tendinopathy stage (normal, reactive/early dysrepair or late dysrepair/degenerative) as well as for individual parameters (thickness, echogenicity and vascularity). Quadratic weighted kappa (kw) was used to report on reliability. Results:Intra-rater reliability was 'substantial' for overall tendinopathy staging (kw rater A; 0.77, 95%?CI 0.59 to 0.94, rater B; 0.70, 95%?CI 0.52 to 0.89) and ranged from 'substantial' to 'almost perfect' for thickness (kw rater A; 0.75, 95%?CI 0.59 to 0.90, rater B; 0.84, 95%?CI 0.71 to 0.98), echogenicity (kw rater A; 0.78, 95%?CI 0.62 to 0.95, rater B; 0.73, 95%?CI 0.58 to 0.89) and vascularity (kw rater A; 0.86, 95%?CI 0.74 to 0.98, rater B; 0.89, 95%?CI 0.79 to 0.99). Inter-rater reliability ranged from 'substantial' to 'almost perfect' for overall tendinopathy staging (kw round 1; 0.75, 95%?CI 0.58 to 0.91, round 2; 0.81, 95%?CI 0.63 to 0.99), thickness (kw round 1; 0.65, 95%?CI 0.48 to 0.83, round 2; 0.77, 95%?CI 0.60 to 0.93), echogenicity (kw round 1; 0.70, 95%?CI 0.54 to 0.85, round 2; 0.76, 95%?CI 0.58 to 0.94) and vascularity (kw round 1; 0.89, 95%?CI 0.79 to 0.99, round 2; 0.86, 95%?CI 0.74 to 0.98). Inter-rater reliability increased from 'substantial' in round 1 (kw 0.75, 95%?CI 0.58 to 0.91) to 'almost perfect' in round 2 (0.81, 95%?CI 0.63 to 0.99). Conclusion:Intra-rater and inter-rater reliability were 'substantial' to 'almost perfect' when utilising an USI-based criteria to diagnose Achilles tendinopathy. This is the first study to use the continuum model of tendon pathology to develop an USI-based criteria to diagnose tendinopathy.

SUBMITTER: Matthews W 

PROVIDER: S-EPMC7173997 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Staging achilles tendinopathy using ultrasound imaging: the development and investigation of a new ultrasound imaging criteria based on the continuum model of tendon pathology.

Matthews Wesley W   Ellis Richard R   Furness James W JW   Rathbone Evelyne E   Hing Wayne W  

BMJ open sport & exercise medicine 20200325 1


<h4>Aim</h4>To develop a standardised ultrasound imaging (USI)-based criteria for the diagnosis of tendinopathy that aligns with the continuum model of tendon pathology. Secondary aims were to assess both the intra-rater and inter-rater reliability of the criteria.<h4>Methods</h4>A criteria was developed following a face validity assessment and a total of 31 Achilles tendon ultrasound images were analysed. Intra-rater and inter-rater reliability were assessed for overall tendinopathy stage (norm  ...[more]

Similar Datasets

| S-EPMC11291231 | biostudies-literature
| S-EPMC6472705 | biostudies-literature
| S-EPMC5373512 | biostudies-literature
| S-EPMC7168329 | biostudies-literature
| S-EPMC8702928 | biostudies-literature
| S-EPMC8285885 | biostudies-literature
| S-EPMC5074891 | biostudies-literature
| S-EPMC6382130 | biostudies-literature
| S-EPMC3558233 | biostudies-other
| S-EPMC4761471 | biostudies-literature