Unknown

Dataset Information

0

Is Heart Rate a Confounding Factor for Photoplethysmography Markers? A Systematic Review.


ABSTRACT: Finger photoplethysmography (PPG) waveform is blood volume change of finger microcirculation that reflects vascular function. Reflection index (RI), stiffness index (SI) and second derivative of photoplethysmogram (SDPPG) are derived from PPG waveforms proposed as cardiovascular disease (CVD) markers. Heart rate (HR) is a known factor that affects vascular function. Individual resting HR variation may affect RI, SI and SDPPG. This review aims to identify studies about the relationship between HR with RI, SI and SDPPG among humans. A literature search was conducted in Medline via the Ebscohost and Scopus databases to find relevant articles published within 11 years. The main inclusion criteria were articles in the English language that discuss the relationship between HR with RI, SI and SDPPG using PPG among humans. The search found 1960 relevant articles but only six articles that met the inclusion criteria. SI and RI showed an association with HR. SDPPG (SDPPG-b/SDPPG-a ratio, SDPPG-d/SDPPG-a ratio, aging index (AGI) and revised aging index (RAGI)) also had an association with HR. Only RI had a considerable association with HR, the association between SI and HR was non-considerable and the association between HR and SDPPG was inconclusive. Further interventional studies should be conducted to investigate this issue, as a variation in resting HR may challenge the validity of PPG-based CVD markers.

SUBMITTER: Md Lazin Md Lazim MR 

PROVIDER: S-EPMC7177218 | biostudies-literature | 2020 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Is Heart Rate a Confounding Factor for Photoplethysmography Markers? A Systematic Review.

Md Lazin Md Lazim Md Rizman MR   Aminuddin Amilia A   Chellappan Kalaivani K   Ugusman Azizah A   Hamid Adila A AA   Wan Ahmad Wan Amir Nizam WAN   Mohamad Mohd Shawal Faizal MSF  

International journal of environmental research and public health 20200410 7


Finger photoplethysmography (PPG) waveform is blood volume change of finger microcirculation that reflects vascular function. Reflection index (RI), stiffness index (SI) and second derivative of photoplethysmogram (SDPPG) are derived from PPG waveforms proposed as cardiovascular disease (CVD) markers. Heart rate (HR) is a known factor that affects vascular function. Individual resting HR variation may affect RI, SI and SDPPG. This review aims to identify studies about the relationship between HR  ...[more]

Similar Datasets

| S-EPMC8160717 | biostudies-literature
| S-EPMC5820156 | biostudies-literature
| S-EPMC6118383 | biostudies-literature
| S-EPMC9712694 | biostudies-literature
| S-EPMC10280337 | biostudies-literature
| S-EPMC9428405 | biostudies-literature
| S-EPMC10175970 | biostudies-literature
| S-EPMC4800007 | biostudies-literature
| S-EPMC6637318 | biostudies-literature
| S-EPMC9028181 | biostudies-literature