New applanation tonometer for myopic patients after laser refractive surgery.


ABSTRACT: This study assesses the agreement between intraocular pressure (IOP) measurements taken with the Goldmann applanation tonometer (GAT) and a new experimental applanation tonometer with a convexly shaped apex (CT) after laser myopic refractive surgery. Two different CT radii (CT1 and CT2) were designed with a finite element analyser, and a prospective double masked study on 102 eyes from 102 patients was carried out. A Bland-Altman plot and intra-class correlation coefficient (ICC) were calculated to assess the agreement between GAT measurements and the measurements of both CT1 and CT2 before and after myopic laser assisted in situ keratomileusis (LASIK; n?=?73) and photorefractive keratectomy (PRK; n?=?29). We evaluated a subset of two subgroups (n?=?36 each) for intra and inter-observer (IA/IE) error. From the whole cohort, the best IOP agreement was observed between GATpre and CT1post surgery: 16.09?±?2.92 vs 16.42?±?2.87 (p??0.8 (95% CI) in all cases. CT1 proved more accurate in the LASIK subgroup. In conclusion, our new version of GAT could be used with post-surgery LASIK patients as a more accurate measurement device compared to the current reference tonometer.

SUBMITTER: Iglesias M 

PROVIDER: S-EPMC7184562 | biostudies-literature | 2020 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

New applanation tonometer for myopic patients after laser refractive surgery.

Iglesias María M   Yebra Francisco F   Kudsieh Bachar B   Laiseca Andrea A   Santos Cristina C   Nadal Jeroni J   Barraquer Rafael R   Casaroli-Marano Ricardo P RP  

Scientific reports 20200427 1


This study assesses the agreement between intraocular pressure (IOP) measurements taken with the Goldmann applanation tonometer (GAT) and a new experimental applanation tonometer with a convexly shaped apex (CT) after laser myopic refractive surgery. Two different CT radii (CT1 and CT2) were designed with a finite element analyser, and a prospective double masked study on 102 eyes from 102 patients was carried out. A Bland-Altman plot and intra-class correlation coefficient (ICC) were calculated  ...[more]

Similar Datasets

| S-EPMC4290199 | biostudies-literature
| S-EPMC4212535 | biostudies-other
| S-EPMC8094180 | biostudies-literature
| S-EPMC4747534 | biostudies-literature
| S-EPMC5415857 | biostudies-literature
| S-EPMC7021678 | biostudies-literature
| S-EPMC7152944 | biostudies-literature