Unknown

Dataset Information

0

Preliminary evaluation of a candidate international reference for Epstein-Barr virus capsid antigen immunoglobulin A in China.


ABSTRACT: Background:The detection of the Epstein-Barr capsid antigen (VCA) immunoglobulin A (IgA) is widely used in the diagnosis of nasopharyngeal carcinoma (NPC), but a reference standard for evaluating the presence of VCA-IgA is not yet available. Therefore, a reference standard is urgently needed for a uniform and quantitative detection of VCA-IgA. Methods:A mixed reference serum from three NPC patients diluted with healthy subject serum was made as a potential first international standard for VCA-IgA. VCA-IgA was detected in twenty NPC patients by four ELISA kits and two chemiluminescent immunoassays kits using the reference as a calibration curve. The performance of these six kits was evaluated, and the quantitative results were compared. Results:Our results showed a good linearity of the reference in different kits. Without reference, the difference of the total coefficient of variation (from 3.98 to 43.11%) and Within-run coefficient of variation (from 2.47 to 19.66%) was large in the 6 kits. The positive and negative coincidence rate between the 6 kits and indirect immunofluorescence for NPC diagnosis was 75% overall agreement, but a difference among the six kits was found, ranging from 55 to 90%. The concentration of VCA-IgA in the 20 NPC samples led in the division into three categories such as negative, low, or medium/high positive, but these concentrations were significantly different within these three categories depending on the kit used of the 6 considered. However,a good correlation (R2?=?0.986) was observed between Antu and Beier ELISA kits. Conclusions:The reference serum mightbe used as a reference standard for a better comparison of the results from different kits/laboratories. However, the quantitative results of some kits are still inconsistent due to the diversity of VCA antigens.

SUBMITTER: Chen H 

PROVIDER: S-EPMC7191735 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Preliminary evaluation of a candidate international reference for Epstein-Barr virus capsid antigen immunoglobulin A in China.

Chen Hao H   Zhong Qiaohua Q   Wu Xiaobin X   Ding Yanling Y   Chen Qi Q   Xue Ning N   Xu Yiwei Y   Chen Shulin S  

Infectious agents and cancer 20200429


<h4>Background</h4>The detection of the Epstein-Barr capsid antigen (VCA) immunoglobulin A (IgA) is widely used in the diagnosis of nasopharyngeal carcinoma (NPC), but a reference standard for evaluating the presence of VCA-IgA is not yet available. Therefore, a reference standard is urgently needed for a uniform and quantitative detection of VCA-IgA.<h4>Methods</h4>A mixed reference serum from three NPC patients diluted with healthy subject serum was made as a potential first international stan  ...[more]

Similar Datasets

| S-EPMC4655226 | biostudies-literature
| S-EPMC3506544 | biostudies-literature
| S-EPMC7546529 | biostudies-literature
| S-EPMC4941321 | biostudies-other
| S-EPMC7608217 | biostudies-literature
2021-11-12 | GSE75198 | GEO
| S-EPMC5899200 | biostudies-literature
2021-08-22 | PXD022970 | Pride
2015-01-06 | E-GEOD-59181 | biostudies-arrayexpress
2015-01-06 | GSE59181 | GEO