Unknown

Dataset Information

0

Field Ion Emission in an Atom Probe Microscope Triggered by Femtosecond-Pulsed Coherent Extreme Ultraviolet Light.


ABSTRACT: This paper describes initial experimental results from an extreme ultraviolet (EUV) radiation-pulsed atom probe microscope. Femtosecond-pulsed coherent EUV radiation of 29.6 nm wavelength (41.85 eV photon energy), obtained through high harmonic generation in an Ar-filled hollow capillary waveguide, successfully triggered controlled field ion emission from the apex of amorphous SiO2 specimens. The calculated composition is stoichiometric within the error of the measurement and effectively invariant of the specimen base temperature in the range of 25 K to 150 K. Photon energies available in the EUV band are significantly higher than those currently used in the state-of-the-art near-ultraviolet laser-pulsed atom probe, which enables the possibility of additional ionization and desorption pathways. Pulsed coherent EUV light is a new and potential alternative to near-ultraviolet radiation for atom probe tomography.

SUBMITTER: Chiaramonti AN 

PROVIDER: S-EPMC7195254 | biostudies-literature | 2020 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Field Ion Emission in an Atom Probe Microscope Triggered by Femtosecond-Pulsed Coherent Extreme Ultraviolet Light.

Chiaramonti Ann N AN   Miaja-Avila Luis L   Caplins Benjamin W BW   Blanchard Paul T PT   Diercks David R DR   Gorman Brian P BP   Sanford Norman A NA  

Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada 20200401 2


This paper describes initial experimental results from an extreme ultraviolet (EUV) radiation-pulsed atom probe microscope. Femtosecond-pulsed coherent EUV radiation of 29.6 nm wavelength (41.85 eV photon energy), obtained through high harmonic generation in an Ar-filled hollow capillary waveguide, successfully triggered controlled field ion emission from the apex of amorphous SiO2 specimens. The calculated composition is stoichiometric within the error of the measurement and effectively invaria  ...[more]

Similar Datasets

| S-EPMC6660206 | biostudies-literature
| S-EPMC6825198 | biostudies-literature
| S-EPMC4258652 | biostudies-literature
| S-EPMC8080687 | biostudies-literature
| S-EPMC7195139 | biostudies-literature
| S-EPMC4751500 | biostudies-other
| S-EPMC5958097 | biostudies-literature
| S-EPMC3644103 | biostudies-other
| S-EPMC10066367 | biostudies-literature
| S-EPMC3791458 | biostudies-literature