Unknown

Dataset Information

0

Analysis of corneal real astigmatism and high order aberration changes that cause visual disturbances after lower eyelid epiblepharon repair surgery.


ABSTRACT: This retrospective, cross-sectional study investigated changes in corneal low and high order aberrations (LOAs and HOAs) after lower eyelid epiblepharon repair surgery. In total, 108 eyes from 54 patients were evaluated. Wavefront analyses for calibrated LOAs and HOAs were performed using a Galilei G4 Dual Scheimpflug Analyzer before surgery and during the first and second follow-ups (f/u), adjusting for several risk factors. Flat keratometry (K) and axis values decreased significantly from baseline at the first f/u. At the second f/u, mean K and axis values decreased. Coma and trefoil increased from baseline at the first f/u and normalized by the second f/u. Spherical aberrations (SA) only decreased at the second f/u. After correction for risk factors, cylinder, coma, trefoil, and SA significantly increased at the first f/u; axis and flat K values decreased. At the second f/u, cylinder increased while axis and mean K values significantly decreased. Epiblepharon repair surgery may result in a shift from 'with-the-rule' to 'against-the-rule' axis change. Flat K, coma, and trefoil may be affected by mechanical force changes immediately post-surgery, while mean K values and SA may also change with corneal state changes including corneal erosion healing after the second f/u during the postoperative period.

SUBMITTER: Lee DC 

PROVIDER: S-EPMC7198593 | biostudies-literature | 2020 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Analysis of corneal real astigmatism and high order aberration changes that cause visual disturbances after lower eyelid epiblepharon repair surgery.

Lee Dong Cheol DC  

Scientific reports 20200504 1


This retrospective, cross-sectional study investigated changes in corneal low and high order aberrations (LOAs and HOAs) after lower eyelid epiblepharon repair surgery. In total, 108 eyes from 54 patients were evaluated. Wavefront analyses for calibrated LOAs and HOAs were performed using a Galilei G4 Dual Scheimpflug Analyzer before surgery and during the first and second follow-ups (f/u), adjusting for several risk factors. Flat keratometry (K) and axis values decreased significantly from base  ...[more]

Similar Datasets

| S-EPMC6754902 | biostudies-literature
| S-EPMC7569024 | biostudies-literature
| S-EPMC6038341 | biostudies-literature
| S-EPMC5056542 | biostudies-literature
| S-EPMC7386813 | biostudies-literature
| S-EPMC9487078 | biostudies-literature
| S-EPMC5548576 | biostudies-other
| S-EPMC6707177 | biostudies-literature
| S-EPMC5800430 | biostudies-literature
| S-EPMC9477362 | biostudies-literature