Unknown

Dataset Information

0

Comparison of next-generation portable pollution monitors to measure exposure to PM2.5 from household air pollution in Puno, Peru.


ABSTRACT: Assessment of personal exposure to PM2.5 is critical for understanding intervention effectiveness and exposure-response relationships in household air pollution studies. In this pilot study, we compared PM2.5 concentrations obtained from two next-generation personal exposure monitors (the Enhanced Children MicroPEM or ECM; and the Ultrasonic Personal Air Sampler or UPAS) to those obtained with a traditional Triplex Cyclone and SKC Air Pump (a gravimetric cyclone/pump sampler). We co-located cyclone/pumps with an ECM and UPAS to obtain 24-hour kitchen concentrations and personal exposure measurements. We measured Spearmen correlations and evaluated agreement using the Bland-Altman method. We obtained 215 filters from 72 ECM and 71 UPAS co-locations. Overall, the ECM and the UPAS had similar correlation (ECM ? = 0.91 vs UPAS ? = 0.88) and agreement (ECM mean difference of 121.7 µg/m3 vs UPAS mean difference of 93.9 µg/m3 ) with overlapping confidence intervals when compared against the cyclone/pump. When adjusted for the limit of detection, agreement between the devices and the cyclone/pump was also similar for all samples (ECM mean difference of 68.8 µg/m3 vs UPAS mean difference of 65.4 µg/m3 ) and personal exposure samples (ECM mean difference of -3.8 µg/m3 vs UPAS mean difference of -12.9 µg/m3 ). Both the ECM and UPAS produced comparable measurements when compared against a cyclone/pump setup.

SUBMITTER: Burrowes VJ 

PROVIDER: S-EPMC7217081 | biostudies-literature | 2020 May

REPOSITORIES: biostudies-literature

altmetric image

Publications


Assessment of personal exposure to PM<sub>2.5</sub> is critical for understanding intervention effectiveness and exposure-response relationships in household air pollution studies. In this pilot study, we compared PM<sub>2.5</sub> concentrations obtained from two next-generation personal exposure monitors (the Enhanced Children MicroPEM or ECM; and the Ultrasonic Personal Air Sampler or UPAS) to those obtained with a traditional Triplex Cyclone and SKC Air Pump (a gravimetric cyclone/pump sample  ...[more]

Similar Datasets

| S-EPMC7658004 | biostudies-literature
| S-EPMC7347290 | biostudies-literature
| S-EPMC8655976 | biostudies-literature
| S-EPMC6671674 | biostudies-literature
| S-EPMC10902506 | biostudies-literature
| S-EPMC8196100 | biostudies-literature
| S-EPMC7468121 | biostudies-literature
| S-EPMC9353663 | biostudies-literature
| S-EPMC5493654 | biostudies-literature
| S-EPMC5093208 | biostudies-literature