Improvement of electrocardiographic diagnostic accuracy of left ventricular hypertrophy using a Machine Learning approach.


ABSTRACT: The electrocardiogram (ECG) is the most common tool used to predict left ventricular hypertrophy (LVH). However, it is limited by its low accuracy (<60%) and sensitivity (30%). We set forth the hypothesis that the Machine Learning (ML) C5.0 algorithm could optimize the ECG in the prediction of LVH by echocardiography (Echo) while also establishing ECG-LVH phenotypes. We used Echo as the standard diagnostic tool to detect LVH and measured the ECG abnormalities found in Echo-LVH. We included 432 patients (power = 99%). Of these, 202 patients (46.7%) had Echo-LVH and 240 (55.6%) were males. We included a wide range of ventricular masses and Echo-LVH severities which were classified as mild (n = 77, 38.1%), moderate (n = 50, 24.7%) and severe (n = 75, 37.1%). Data was divided into a training/testing set (80%/20%) and we applied logistic regression analysis on the ECG measurements. The logistic regression model with the best ability to identify Echo-LVH was introduced into the C5.0 ML algorithm. We created multiple decision trees and selected the tree with the highest performance. The resultant five-level binary decision tree used only six predictive variables and had an accuracy of 71.4% (95%CI, 65.5-80.2), a sensitivity of 79.6%, specificity of 53%, positive predictive value of 66.6% and a negative predictive value of 69.3%. Internal validation reached a mean accuracy of 71.4% (64.4-78.5). Our results were reproduced in a second validation group and a similar diagnostic accuracy was obtained, 73.3% (95%CI, 65.5-80.2), sensitivity (81.6%), specificity (69.3%), positive predictive value (56.3%) and negative predictive value (88.6%). We calculated the Romhilt-Estes multilevel score and compared it to our model. The accuracy of the Romhilt-Estes system had an accuracy of 61.3% (CI95%, 56.5-65.9), a sensitivity of 23.2% and a specificity of 94.8% with similar results in the external validation group. In conclusion, the C5.0 ML algorithm surpassed the accuracy of current ECG criteria in the detection of Echo-LVH. Our new criteria hinge on ECG abnormalities that identify high-risk patients and provide some insight on electrogenesis in Echo-LVH.

SUBMITTER: De la Garza-Salazar F 

PROVIDER: S-EPMC7219774 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Improvement of electrocardiographic diagnostic accuracy of left ventricular hypertrophy using a Machine Learning approach.

De la Garza-Salazar Fernando F   Romero-Ibarguengoitia Maria Elena ME   Rodriguez-Diaz Elias Abraham EA   Azpiri-Lopez Jose Ramón JR   González-Cantu Arnulfo A  

PloS one 20200513 5


The electrocardiogram (ECG) is the most common tool used to predict left ventricular hypertrophy (LVH). However, it is limited by its low accuracy (<60%) and sensitivity (30%). We set forth the hypothesis that the Machine Learning (ML) C5.0 algorithm could optimize the ECG in the prediction of LVH by echocardiography (Echo) while also establishing ECG-LVH phenotypes. We used Echo as the standard diagnostic tool to detect LVH and measured the ECG abnormalities found in Echo-LVH. We included 432 p  ...[more]

Similar Datasets

| S-EPMC8029852 | biostudies-literature
| S-EPMC2525851 | biostudies-other
| S-EPMC8169892 | biostudies-literature
| S-EPMC5291170 | biostudies-literature
| S-EPMC3202073 | biostudies-literature
| S-EPMC5549337 | biostudies-literature
| S-EPMC8803820 | biostudies-literature
| S-EPMC8631676 | biostudies-literature
| S-EPMC5861536 | biostudies-literature
| S-EPMC6931489 | biostudies-literature