Project description:Video 1Demonstration of gastric endoscopic submucosal dissection using the pocket-creation method at the angle along the lesser curvature and fornix.
Project description:Background and aims:Endoscopic submucosal dissection (ESD) is the preferred technique for en bloc resection of superficial colorectal neoplasms. Resection of extensive lesions with ESD can be challenging, owing to loss of orientation in the submucosal space. In this case series, we describe the double-tunneling (DoT) butterfly method for ESD of extensive rectal neoplasms. Methods:The key feature of the DoT butterfly method is the creation of 2 tunnels that are transformed into bilateral flaps, leaving a submucosal septum between them. Results:Four rectal neoplasms measuring (maximum diameter) 7 cm, 8 cm, 9 cm, and 18 cm, respectively, were resected in 4 patients by use of the DoT butterfly method. The lesions included recurrent adenoma (n = 1) and dysplasia (n = 1) in longstanding ulcerative colitis. Curative R0 resection was confirmed in all 4 cases. Histologic examination showed tubular adenomas with low-grade dysplasia in 1 of 4 patients and focal high-grade dysplasia in 3 of 4 patients. One patient experienced postprocedural bleeding that required endoscopic reintervention. Conclusion:The DoT butterfly method appears to be useful for the resection of extensive rectal neoplasms. A prospective study is required to assess whether these results can be reproduced in a large cohort of patients.
Project description:BackgroundThe lack of countertraction in endoscopic submucosal dissection (ESD) results in increased technical demand and procedure time. Although the suture-pulley method for countertraction has been reported, its effectiveness compared with the traditional ESD technique remains unclear.ObjectiveTo objectively analyze efficacy of countertraction using the suture-pulley method for ESD.DesignProspective ex vivo animal study.SettingAnimal laboratory.InterventionsTwenty simulated gastric lesions were created in porcine stomachs by using a standard circular template 30 mm in diameter. In the control arm (n = 10), ESD was performed by using the standard technique. In the suture-pulley arm (N = 10), a circumferential incision was made, and an endoscopic suturing device was used to place the suture pulley.Main outcome measurementsThe primary outcome of this study was total procedure time.ResultsThe median total procedure time with the suture-pulley method was significantly shorter than the traditional ESD technique (median, 25% to 75%, interquartile range [IQR]: 531 seconds [474.3-549.3 seconds] vs 845 seconds [656.3-1547.5 seconds], P < .001). The median time (IQR) for suture-pulley placement was 160.5 seconds (150.0-168.8 seconds). Although there was a significantly longer procedure time for proximal versus middle/lower stomach lesions with traditional ESD (median, 1601 seconds; IQR, 1547.5-1708.8 seconds vs median, 663 seconds; IQR, 627.5-681.8 seconds; P = .01), there was no significant difference in procedure time for lesions of various locations when using the suture-pulley method. Compared with traditional ESD, the suture-pulley method was less demanding in all categories evaluated by the NASA Task Load Index.LimitationsEx vivo study.ConclusionsThe suture-pulley method facilitates direct visualization of the submucosal layer during ESD and significantly reduces procedure time and technical difficulty. In addition, the benefit of the suture-pulley method was seen for both simple and more complicated ESDs.
Project description:BackgroundInsufficient countertraction and poor field of vision make endoscopic submucosal dissection (ESD) difficult. Internal traction method using a spring-and-loop with clip (SLC) allows sufficient traction in any direction and good field of vision. However, the attachment procedure is difficult and interference with the endoscope can occur in the retroflexed endoscopic position. We have developed a new use of SLC that simplifies the attachment procedure, eliminating interference with the endoscope. The aim of this study was to investigate the efficacy of SLC for gastric ESD.MethodsWe retrospectively recruited 140 patients with gastric neoplasms who underwent ESD between November 2015 and October 2018 at our department. Among them, 51 patients treated using SLC-assisted ESD (SLC-ESD) and 89 patients treated using conventional ESD (C-ESD) were compared. Propensity score matching was performed to compensate for the differences in age, sex, lesion location, lesion position, specimen size, and ulcer findings. The primary outcome was ESD procedure time.ResultsPropensity score matching generated 51 matched pairs. The procedure time in the SLC-ESD group was significantly shorter than that in the C-ESD group (median [interquartile], 40.0 [27.0-81.5] minutes versus 69.0 [46.5-113.5] minutes, P = 0.008). The mean SLC attachment time was 2.08 min. There were no significant differences in complete en bloc resection rate between SLC-ESD and C-ESD groups (100% versus 96.1%, P = 0.495). There were not perforation cases in either group.ConclusionsSLC may offer an efficient method for gastric ESD, with a short attachment procedure time.