Unknown

Dataset Information

0

3D-Reconstruction of the human conventional outflow system by ribbon scanning confocal microscopy.


ABSTRACT: PURPOSE:The risk for glaucoma is driven by the microanatomy and function of the anterior segment. We performed a computation-intense, high-resolution, full-thickness ribbon-scanning confocal microscopy (RSCM) of the outflow tract of two human eyes. We hypothesized this would reveal important species differences when compared to existing data of porcine eyes, an animal that does not spontaneously develop glaucoma. METHODS:After perfusing two human octogenarian eyes with lectin-fluorophore conjugate and optical clearance with benzyl alcohol benzyl benzoate (BABB), anterior segments were scanned by RSCM and reconstructed in 3D for whole-specimen rendering. Morphometric analyses of the outflow tract were performed for the trabecular meshwork (TM), limbal, and perilimbal outflow structures and compared to existing porcine data. RESULTS:RSCM provided high-resolution data for IMARIS-based surface reconstruction of outflow tract structures in 3D. Different from porcine eyes with an abundance of highly interconnected, narrow, and short collector channels (CCs), human eyes demonstrated fewer CCs which had a 1.5x greater cross-sectional area (CSA) and 2.6x greater length. Proximal CC openings at the level of Schlemm's canal (SC) had a 1.3x larger CSA than distal openings into the scleral vascular plexus (SVP). CCs were 10.2x smaller in volume than the receiving SVP vessels. Axenfeld loops, projections of the long ciliary nerve, were also visualized. CONCLUSION:In this high-resolution, volumetric RSCM analysis, human eyes had far fewer outflow tract vessels than porcine eyes. Human CCs spanned several clock-hours and were larger than in porcine eyes. These species differences may point to factors downstream of the TM that increase our vulnerability to glaucoma.

SUBMITTER: Loewen RT 

PROVIDER: S-EPMC7233539 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

3D-Reconstruction of the human conventional outflow system by ribbon scanning confocal microscopy.

Loewen Ralitsa T RT   Waxman Susannah S   Wang Chao C   Atta Sarah S   Chen Si S   Watkins Simon C SC   Watson Alan M AM   Loewen Nils A NA  

PloS one 20200518 5


<h4>Purpose</h4>The risk for glaucoma is driven by the microanatomy and function of the anterior segment. We performed a computation-intense, high-resolution, full-thickness ribbon-scanning confocal microscopy (RSCM) of the outflow tract of two human eyes. We hypothesized this would reveal important species differences when compared to existing data of porcine eyes, an animal that does not spontaneously develop glaucoma.<h4>Methods</h4>After perfusing two human octogenarian eyes with lectin-fluo  ...[more]

Similar Datasets

| S-EPMC6026296 | biostudies-literature
| S-EPMC8593100 | biostudies-literature
| S-EPMC5501561 | biostudies-literature
| S-EPMC5945773 | biostudies-literature
| S-EPMC7056675 | biostudies-literature
| S-EPMC2587633 | biostudies-literature
| S-EPMC6512973 | biostudies-literature
| S-EPMC10457288 | biostudies-literature
| S-EPMC3945399 | biostudies-literature
| S-EPMC3093556 | biostudies-other