Unknown

Dataset Information

0

Integrated Digital Microfluidic Platform for Colorimetric Sensing of Nitrite.


ABSTRACT: In this paper, a palm-size digital microfluidic (DMF) platform integrated with colorimetric analysis was developed for quantifying the concentration of nitrite. To realize the on-chip repeatable colorimetric analysis, a novel printed circuit board (PCB)-based DMF chip was designed with an embedded aperture on the actuator electrode, forming a vertical light path for online measurement of the droplets. The capabilities of the DMF platform enable automatic manipulation of microliter-level droplets to implement Griess assay without the use of external systems such as syringe, pump, or valve, which provides the benefits including high flexibility, portability, miniature size, and low cost. Results indicated the characteristics of good linearity (R 2 = 0.9974), the ignorable crosstalk for reusability, and the limit of detection (LOD) of nitrite as low as 5 ?g/L. Furthermore, the presented platform was successfully applied to determine nitrite levels in food products with reliable results and satisfactory recoveries. This integrated DMF platform can be a promising new tool for a wide range of applications involving step-by-step solution mixing and optical detection in environmental monitoring, food safety analysis, and point-of-care testing.

SUBMITTER: Gu Z 

PROVIDER: S-EPMC7241042 | biostudies-literature | 2020 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Integrated Digital Microfluidic Platform for Colorimetric Sensing of Nitrite.

Gu Zhen Z   Wu Ming-Lei ML   Yan Bing-Yong BY   Wang Hui-Feng HF   Kong Cong C  

ACS omega 20200504 19


In this paper, a palm-size digital microfluidic (DMF) platform integrated with colorimetric analysis was developed for quantifying the concentration of nitrite. To realize the on-chip repeatable colorimetric analysis, a novel printed circuit board (PCB)-based DMF chip was designed with an embedded aperture on the actuator electrode, forming a vertical light path for online measurement of the droplets. The capabilities of the DMF platform enable automatic manipulation of microliter-level droplets  ...[more]

Similar Datasets

| S-EPMC8433351 | biostudies-literature
| S-EPMC6925289 | biostudies-literature
| S-EPMC10046291 | biostudies-literature
| S-EPMC4371189 | biostudies-literature
| S-EPMC2917228 | biostudies-literature
| S-EPMC8635524 | biostudies-literature
| S-EPMC8950014 | biostudies-literature
| S-EPMC5429097 | biostudies-literature
| S-EPMC2859674 | biostudies-literature
| S-EPMC6412725 | biostudies-literature