Using computerized assessment in simulated colonoscopy: a validation study.


ABSTRACT: Background and study aims? Patient safety during a colonoscopy highly depends on endoscopist competence. Endoscopic societies have been calling for an objective and regular assessment of the endoscopists, but existing assessment tools are time-consuming and prone to bias. We aimed to develop and gather evidence of validity for a computerized assessment tool delivering automatic and unbiased assessment of colonoscopy based on 3 dimensional coordinates from the colonoscope. Methods? Twenty-four participants were recruited and divided into two groups based on experience: 12 experienced and 12 novices. Participants performed twice on a physical phantom model with a standardized alpha loop in the sigmoid colon. Data was gathered directly from the Olympus ScopeGuide system providing XYZ-coordinates along the length of the colonoscope. Five different motor skill measures were developed based on the data, named: Travel Length, Tip Progression, Chase Efficiency, Shaft movement without tip progression, and Looping. Results? The experinced had a lower travel length ( P ?

SUBMITTER: Vilmann AS 

PROVIDER: S-EPMC7247901 | biostudies-literature | 2020 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Using computerized assessment in simulated colonoscopy: a validation study.

Vilmann Andreas Slot AS   Lachenmeier Christian C   Svendsen Morten Bo Søndergaard MBS   Søndergaard Bo B   Park Yoon Soo YS   Svendsen Lars Bo LB   Konge Lars L  

Endoscopy international open 20200525 6


<b>Background and study aims </b> Patient safety during a colonoscopy highly depends on endoscopist competence. Endoscopic societies have been calling for an objective and regular assessment of the endoscopists, but existing assessment tools are time-consuming and prone to bias. We aimed to develop and gather evidence of validity for a computerized assessment tool delivering automatic and unbiased assessment of colonoscopy based on 3 dimensional coordinates from the colonoscope. <b>Methods </b>  ...[more]

Similar Datasets

| S-EPMC7666442 | biostudies-literature
| S-EPMC10953101 | biostudies-literature
| S-EPMC7090282 | biostudies-literature
| S-EPMC1247700 | biostudies-literature
| PRJEB31817 | ENA
| S-EPMC7534185 | biostudies-literature
| S-EPMC8084426 | biostudies-literature
| PRJEB33194 | ENA
| S-EPMC8922138 | biostudies-literature
| S-EPMC8295558 | biostudies-literature