Unknown

Dataset Information

0

Impact of Electronic Alternatives to Tobacco Cigarettes on Indoor Air Particular Matter Levels.


ABSTRACT: An aerosol study was carried out in a test room measuring particulate matter (PM) with an aerodynamic diameter smaller than 10, 4, 2.5 and 1 µm (PM10, PM4, PM2.5, PM1) before and during the use of electronic alternatives to tobacco cigarettes (EATC) IQOS®, GLO®, JUUL®, with different kinds of sticks/pods, as well as during the smoking of a conventional tobacco cigarette. The aerosol was mainly in the PM1 size range (>95%). All studied EATCs caused lower indoor PM1 concentrations than conventional tobacco cigarettes. Nevertheless, they determined a worsening of indoor-PM1 concentration that ranged from very mild for JUUL®-depending on the pod used-to considerably severe for IQOS® and GLO®. Median values ranged from 11.00 (Iqos3 and Juul2) to 337.5 µg m-3 (Iqos4). The high variability of particle loadings was attributed both to the type of stick/pod used and to the different way of smoking of volunteers who smoked/vaped during the experiments. Moreover, during vaping IQOS® and GLO® indoor PM1 concentrations reach levels by far higher than outdoor concentrations that range from 14 to 21 µg m-3, especially during the exhalation of the smoke. From these results emerge an urgent need of a legislative regulation limiting the use of such devices in public places.

SUBMITTER: Protano C 

PROVIDER: S-EPMC7254302 | biostudies-literature | 2020 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Impact of Electronic Alternatives to Tobacco Cigarettes on Indoor Air Particular Matter Levels.

Protano Carmela C   Manigrasso Maurizio M   Cammalleri Vittoria V   Biondi Zoccai Giuseppe G   Frati Giacomo G   Avino Pasquale P   Vitali Matteo M  

International journal of environmental research and public health 20200424 8


An aerosol study was carried out in a test room measuring particulate matter (PM) with an aerodynamic diameter smaller than 10, 4, 2.5 and 1 µm (PM<sub>10</sub>, PM<sub>4</sub>, PM<sub>2.5</sub>, PM<sub>1</sub>) before and during the use of electronic alternatives to tobacco cigarettes (EATC) IQOS<sup>®</sup>, GLO<sup>®</sup>, JUUL<sup>®</sup>, with different kinds of sticks/pods, as well as during the smoking of a conventional tobacco cigarette. The aerosol was mainly in the PM<sub>1</sub> size  ...[more]

Similar Datasets

| S-EPMC7346849 | biostudies-literature
2019-08-21 | GSE118431 | GEO
| PRJNA485536 | ENA
| S-EPMC6928567 | biostudies-literature
| S-EPMC6251645 | biostudies-literature
| S-EPMC6343856 | biostudies-literature