Differentiation between mechanically loose and fixed press-fit implants using quantitative acoustics and load self-referencing: A phantom study on shoulder prostheses in polyurethane foam.


ABSTRACT: This study proposes to use cross-interface quantitative acoustics (ci-qA) and load self-referencing (LSR) to assess implant stability in a radiation-free, inexpensive, rapid, and quantitative manner. Eight bone analog specimens, made from polyurethane foam, were implanted with a cementless stemless shoulder implant-first in a fixed and later in a loose configuration-and measured using ci-qA under two load conditions. The loose implants exhibited higher micromotion and lower pull-out strength than their stable counterparts, with all values falling within the range of reported reference values. All acoustic characteristics differentiated between loose and fixed implants (maximum area-under-curve AUC = 1.0 for mean total signal energy, AUC = 1.0 for mean total signal energy ratio, AUC = 0.8 for harmonic ratio, and AUC = 0.92 for load self-referencing coefficient). While these results on bone substitute material will need to be confirmed on real bone specimen, ci-qA could ultimately facilitate the assessment of primary stability during implantation surgery and avoid unnecessary revision through quantitative evaluation of secondary stability during follow-up.

SUBMITTER: Vogl F 

PROVIDER: S-EPMC7259646 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Differentiation between mechanically loose and fixed press-fit implants using quantitative acoustics and load self-referencing: A phantom study on shoulder prostheses in polyurethane foam.

Vogl Florian F   Greger Stefanie S   Favre Philippe P   Taylor William R WR   Thistlethwaite Paul P  

PloS one 20200529 5


This study proposes to use cross-interface quantitative acoustics (ci-qA) and load self-referencing (LSR) to assess implant stability in a radiation-free, inexpensive, rapid, and quantitative manner. Eight bone analog specimens, made from polyurethane foam, were implanted with a cementless stemless shoulder implant-first in a fixed and later in a loose configuration-and measured using ci-qA under two load conditions. The loose implants exhibited higher micromotion and lower pull-out strength tha  ...[more]

Similar Datasets

| S-EPMC9736621 | biostudies-literature
| PRJEB54959 | ENA
| S-EPMC9593988 | biostudies-literature
| S-EPMC9933227 | biostudies-literature
| S-EPMC8071504 | biostudies-literature
| S-EPMC7725265 | biostudies-literature
| S-EPMC4626495 | biostudies-literature
| S-EPMC6985010 | biostudies-literature
| S-EPMC7062258 | biostudies-literature
| S-EPMC4222382 | biostudies-literature