Efficacy and safety of flash glucose monitoring in patients with type 1 and type 2 diabetes: a systematic review and meta-analysis.


ABSTRACT: INTRODUCTION:Flash glucose monitoring (FGM) is a factory-calibrated sensor-based technology for the measurement of interstitial glucose. We performed a systematic review and meta-analysis to assess its efficacy and safety in patients with type 1 and type 2 diabetes. RESEARCH DESIGN AND METHODS:PubMed, CENTRAL, Scopus and Web of Science were searched in July 2019. Twelve studies with a follow-up longer than 8?weeks, evaluating 2173 patients on prandial insulin, multiple daily insulin injections or continuous subcutaneous insulin infusion were included. The following data were extracted: HbA1c, time in range, time above 180?mg/dL, time below 70?mg/dL, frequency of hypoglycemic events, number of self-monitoring of blood glucose (SMBG) measurements, total daily insulin dose, patient-reported outcomes, adverse events, and discontinuation rate. A comparison with SMBG was conducted. RESULTS:FGM use was associated with a reduction in HbA1c (-0.26% (-3 mmol/mol); p=0.002) from baseline to the last available follow-up, which correlated with HbA1c levels at baseline (-0.4% (-4 mmol/mol) for each 1.0% (11 mmol/mol) of HbA1c above 7.2% (55 mmol/mol)). Also, a decrease in time below 70?mg/dL was found (-0.60?hours/day; p=0.04). Favorable findings in patient-reported outcomes and no device-related serious adverse events were reported. When compared with SMBG, FGM was characterized by no statistically different change in HbA1c (p=0.09), with lower number of SMBG measurements per day (-3.76?n/day; p<0.001) and risk of discontinuation (relative risk=0.42; p=0.001). A limited number of studies, with a heterogeneous design and usually with a short-term follow-up and without specific training, were found. CONCLUSIONS:The present review provides evidence for the use of FGM as an effective strategy for the management of diabetes.

SUBMITTER: Castellana M 

PROVIDER: S-EPMC7265013 | biostudies-literature | 2020 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Efficacy and safety of flash glucose monitoring in patients with type 1 and type 2 diabetes: a systematic review and meta-analysis.

Castellana Marco M   Parisi Claudia C   Di Molfetta Sergio S   Di Gioia Ludovico L   Natalicchio Annalisa A   Perrini Sebastio S   Cignarelli Angelo A   Laviola Luigi L   Giorgino Francesco F  

BMJ open diabetes research & care 20200601 1


<h4>Introduction</h4>Flash glucose monitoring (FGM) is a factory-calibrated sensor-based technology for the measurement of interstitial glucose. We performed a systematic review and meta-analysis to assess its efficacy and safety in patients with type 1 and type 2 diabetes.<h4>Research design and methods</h4>PubMed, CENTRAL, Scopus and Web of Science were searched in July 2019. Twelve studies with a follow-up longer than 8 weeks, evaluating 2173 patients on prandial insulin, multiple daily insul  ...[more]

Similar Datasets

| S-EPMC6592598 | biostudies-literature
| S-EPMC7644607 | biostudies-literature
| S-EPMC7164995 | biostudies-literature
| S-EPMC8811446 | biostudies-literature
| S-EPMC6778578 | biostudies-literature
| S-EPMC9402979 | biostudies-literature
| S-EPMC10931178 | biostudies-literature
| S-EPMC6939983 | biostudies-literature
| S-EPMC5963790 | biostudies-literature
| S-EPMC4705511 | biostudies-literature