Project description:Video 1Video depicts EUS-guided choledochoduodenostomy creation using a biliary fully covered self-expanding metal stent after maldeployment of a lumen-apposing metal stent.
Project description:Video 1Narration of case and demonstration of the endoscopic management of an embedded stent with stent-in-stent technique to induce pressure necrosis, followed by a combination of needle-knife electroincision, argon plasma coagulation, stent intubation and transection with the gastroscope shaft, and cold and hot snare resection.
Project description:Background and aimsPlacing a lumen-apposing metal stent (LAMS) through ascites carries serious risks, including death from leakage around the LAMS and failure to create a mature fistula between the 2 lumens. However, sometimes no options exist or are equally dangerous. We present 5 patients who underwent LAMS placement despite ascites in 2 different locations.MethodsThis is a retrospective review of 5 patients who underwent LAMS placement despite ascites in 2 different locations from 2016 to 2018.ResultsThree patients with cholecystitis and 2 patients with afferent limb syndrome and severe ascites were treated with a combination of preprocedural and intraprocedural paracentesis. Serum ascites albumin gradient was measured. Weight was recorded daily. Patients were encouraged to sleep at an incline, and periodic paracentesis (every 3-7 days) was performed when ascites reaccumulated over 4 weeks. Median volume of ascites aspirated was 2 L preprocedurally and 300 mL intraprocedurally. Only 1 patient had ascites with a high serum ascites albumin gradient and was treated with diuretics. Technical and clinical success was achieved in all 5 patients without any adverse events over a median follow-up of 28 weeks.ConclusionsIn situations in which no better options remain, LAMS placement appears to be safe after adequate and aggressive treatment of the underlying ascites pre-, intra-, and postprocedurally. Larger studies are needed to establish the safety of this approach.
Project description:Background and aimsLumen-apposing metal stents (LAMSs) play an increasing role in transgastric and transduodenal drainage of pancreatic fluid collections and allow novel EUS-guided interventions. Alongside the main adverse events of bleeding and occlusion, LAMSs can be overgrown by mucosa, which leads to the inability to visualize the stent in endoscopy.MethodsWe describe a series of 4 cases of buried LAMSs that were removed under EUS guidance for identification of the stent followed by removal with rat-tooth forceps.ResultsThe median in situ time of the LAMSs in the reported 4 cases was 53 days. All stents could no longer be visualized endoscopically when drainage of necrosis was complete. All 4 buried LAMSs could be identified by EUS and were removed successfully with forceps. In 1 case, balloon dilation of the stent tract was performed before stent removal. No adverse events were observed after the procedure.ConclusionsBuried stent syndrome is a rare adverse event of LAMSs. Here we describe a safe and effective approach for stent identification and removal without prior mucosal dissection.