Unknown

Dataset Information

0

Two-Dimensional Shear Wave Elastography versus Transient Elastography: A Non-Invasive Comparison for the Assessment of Liver Fibrosis in Patients with Chronic Hepatitis C.


ABSTRACT: In recent years, several non-invasive methods have been developed for staging liver fibrosis in patients with chronic hepatitis C. A 2D-Shear wave elastography (SWE) technique has been recently introduced on the EPIQ 7 US system (ElastQ), but its accuracy has not been validated in patients with chronic hepatitis C virus (HCV) infection. We enrolled 178 HCV patients to assess their liver fibrosis stage with ElastQ software using transient elastography as a reference standard. The best cut-off values to diagnose ³ F2, ³ F3, and F4 were 8.15, 10.31, and 12.65 KPa, respectively. Liver stiffness values had a positive correlation with transient elastography (r = 0.57; p < 0.001). The area under the receiver operating characteristics (AUROC) was 0.899 for ³ F2 (moderate fibrosis), 0.900 for ³ F3 (severe fibrosis), and 0.899 for cirrhosis. 2D-SWE has excellent accuracy in assessing liver fibrosis in patients with chronic hepatitis C and an excellent correlation with transient elastography.

SUBMITTER: Villani R 

PROVIDER: S-EPMC7277963 | biostudies-literature | 2020 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Two-Dimensional Shear Wave Elastography versus Transient Elastography: A Non-Invasive Comparison for the Assessment of Liver Fibrosis in Patients with Chronic Hepatitis C.

Villani Rosanna R   Cavallone Francesco F   Romano Antonino Davide AD   Bellanti Francesco F   Serviddio Gaetano G  

Diagnostics (Basel, Switzerland) 20200516 5


In recent years, several non-invasive methods have been developed for staging liver fibrosis in patients with chronic hepatitis C. A 2D-Shear wave elastography (SWE) technique has been recently introduced on the EPIQ 7 US system (ElastQ), but its accuracy has not been validated in patients with chronic hepatitis C virus (HCV) infection. We enrolled 178 HCV patients to assess their liver fibrosis stage with ElastQ software using transient elastography as a reference standard. The best cut-off val  ...[more]

Similar Datasets

| S-EPMC8504217 | biostudies-literature
| S-EPMC9311739 | biostudies-literature
| S-EPMC7062958 | biostudies-literature
| S-EPMC5051706 | biostudies-literature
| S-EPMC10331060 | biostudies-literature
| S-EPMC10102744 | biostudies-literature
| S-EPMC8761995 | biostudies-literature
| S-EPMC7483774 | biostudies-literature
| S-EPMC9299715 | biostudies-literature
| S-EPMC5765493 | biostudies-literature