Unknown

Dataset Information

0

Precision Targeted Ablation of Fine Neurovascular Structures In Vivo Using Dual-mode Ultrasound Arrays.


ABSTRACT: Carotid bodies (CBs) are chemoreceptors that monitor and register changes in the blood, including the levels of oxygen, carbon dioxide, and pH, and regulate breathing. Enhanced activity of CBs was shown to correlate with a significant elevation in the blood pressure of patients with hypertension. CB removal or denervation were previously shown to reduce hypertension. Here we demonstrate the feasibility of a dual-mode ultrasound array (DMUA) system to safely ablate the CB in vivo in a spontaneously hypertensive rat (SHR) model of hypertension. DMUA imaging was used for guiding and monitoring focused ultrasound (FUS) energy delivered to the target region. In particular, 3D imaging was used to identify the carotid bifurcation for targeting the CBs. Intermittent, high frame rate imaging during image-guided FUS (IgFUS) delivery was used for monitoring the lesion formation. DMUA imaging provided feedback for closed-loop control (CLC) of the lesion formation process to avoid overexposure. The procedure was tolerated well in over 100 SHR and normotensive rats that received unilateral and bilateral treatments. The measured mean arterial pressure (MAP) exhibited measurable deviation from baseline 2-4 weeks post IgFUS treatment. The results suggest that the direct unilateral FUS treatment of the CB might be sufficient to reduce the blood pressure in hypertensive rats and justify further investigation in large animals and eventually in human patients.

SUBMITTER: Aravalli RN 

PROVIDER: S-EPMC7280193 | biostudies-literature | 2020 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Precision Targeted Ablation of Fine Neurovascular Structures In Vivo Using Dual-mode Ultrasound Arrays.

Aravalli Rajagopal N RN   Helden Dusty Van DV   Liu Dalong D   O'Brien Parker P   Aldiabat Hasan H   Tăbăran Alexandru-Flaviu AF   O'Sullivan M Gerard MG   Clark H Brent HB   Osborn John W JW   Ebbini Emad S ES  

Scientific reports 20200608 1


Carotid bodies (CBs) are chemoreceptors that monitor and register changes in the blood, including the levels of oxygen, carbon dioxide, and pH, and regulate breathing. Enhanced activity of CBs was shown to correlate with a significant elevation in the blood pressure of patients with hypertension. CB removal or denervation were previously shown to reduce hypertension. Here we demonstrate the feasibility of a dual-mode ultrasound array (DMUA) system to safely ablate the CB in vivo in a spontaneous  ...[more]

Similar Datasets

| S-EPMC7793556 | biostudies-literature
| S-EPMC6455005 | biostudies-literature
| S-EPMC5627974 | biostudies-literature
| S-EPMC10981753 | biostudies-literature
| S-EPMC6821736 | biostudies-literature
| S-EPMC11338274 | biostudies-literature
| S-EPMC6041475 | biostudies-literature
| S-EPMC3779652 | biostudies-literature
| S-EPMC6212853 | biostudies-literature
| S-EPMC3524551 | biostudies-literature