A Novel Microchip Flow Chamber (Total Thrombus Analysis System) to Assess Canine Hemostasis.


ABSTRACT: Hemorrhagic diseases are common in dogs. Current coagulation assays do not model all aspects of in vivo hemostasis and may not predict bleeding risk. The Total-Thrombus Analysis System (T-TAS) is a novel hemostasis assay system in which whole blood flows through microfluidic channels at defined shear rates to provide qualitative and quantitative evaluation of platelet function (PL-chip) and coagulation function (AR-chip). The present study evaluated the T-TAS in dogs with hereditary bleeding disorders and with acquired hemorrhagic syndromes (Group 1), and healthy controls (Group 2). Hereditary defects included von Willebrand's disease (VWD; n = 4), hemophilia A (n = 2), and canine Scott syndrome (n = 2). Acquired hemorrhagic disorders included neoplastic hemoperitoneum (n = 2) and acute hemorrhagic diarrhea syndrome (n = 1). Citrate anticoagulated samples were collected from diseased dogs (Group 1, n = 11) and controls (Group 2, n = 11) for coagulation screening tests, fibrinogen analyses, D-dimer concentration, antithrombin activity, von Willebrand Factor antigen, PFA-100 closure time (PFA-CT), and thromboelastography (TEG). Citrate and hirudin anticoagulated samples were used for T-TAS analyses at two shear rates. Qualitative thrombus formation in each chip was recorded using the T-TAS video camera. Numeric parameters, derived from the instrument software, included occlusion start time (OST; time to 10 kPa), occlusion time (OT; time to 60 kPa (PL-chip) or 80 kPa (AR-chip)), and area under the pressure curve (AUC). Correlations between continuous variables were evaluated by Spearman's rank. Continuous variables were compared between groups by Student's t-test or the Mann-Whitney U-test. Alpha was set at 0.05. In combined analyses of all dogs, significant correlations were identified between T-TAS variables, between the PFA-CT and PL-chip parameters and between TEG variables and AR-chip parameters. The prothrombin time correlated with the AR-chip AUC at both shear rates. In Group 1 dogs, the AR-chip AUC at low shear was significantly reduced compared with Group 2 dogs. Aberrant thrombus formation was seen in video images recorded from dogs with VWD and hemophilia A. The T-TAS AR-chip analysis distinguished dogs with bleeding risk compared to healthy controls. Initial evaluations of the T-TAS suggest it may aid characterization of hemostasis in patients at-risk of bleeding and assist with delineating bleeding phenotypes.

SUBMITTER: Iwanaga T 

PROVIDER: S-EPMC7282356 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

A Novel Microchip Flow Chamber (Total Thrombus Analysis System) to Assess Canine Hemostasis.

Iwanaga Tomoko T   Miura Naoki N   Brainard Benjamin M BM   Brooks Marjory B MB   Goggs Robert R  

Frontiers in veterinary science 20200602


Hemorrhagic diseases are common in dogs. Current coagulation assays do not model all aspects of <i>in vivo</i> hemostasis and may not predict bleeding risk. The Total-Thrombus Analysis System (T-TAS) is a novel hemostasis assay system in which whole blood flows through microfluidic channels at defined shear rates to provide qualitative and quantitative evaluation of platelet function (PL-chip) and coagulation function (AR-chip). The present study evaluated the T-TAS in dogs with hereditary bleed  ...[more]

Similar Datasets

| S-EPMC5547037 | biostudies-other
| S-EPMC6717975 | biostudies-literature
| S-EPMC6504681 | biostudies-other
| S-EPMC3769405 | biostudies-other
| S-EPMC4007613 | biostudies-literature
| S-EPMC5457037 | biostudies-literature
| S-EPMC2851412 | biostudies-literature
| S-EPMC8570056 | biostudies-literature
| S-EPMC6531446 | biostudies-literature
| S-EPMC9739204 | biostudies-literature