Prediction and discrimination of skeletal muscle function by bioelectrical impedance vector analysis using a standing impedance analyzer in healthy Taiwanese adults.


ABSTRACT:

Background

Bioelectrical impedance vector analysis (BIVA) has been used for prediction of muscle performance. However, little is known about BIVA in Asian adults, and even less is known about using standing BIVA devices. Standing impedance analyzer allows quicker and more convenient way to gather data than conventional supine analyzer and is more suitable for clinical practice. This study aimed to investigate the relations between muscle function and BIVA parameters measured with a standing impedance analyzer in healthy Taiwanese adults.

Methods

A total of 406 healthy subjects (age 34.5 ± 17.3 years, body mass index 24.1 ± 4.1 kg/m2) were recruited for BIVA and handgrip strength (HGS) measurements. Impedance parameters, including resistance (R) and reactance (Xc), were measured and normalized to body size by dividing by height (H). The resulting phase angle (PhA) was calculated. HGS in the dominant, left, and right hands were referred to as HGSDH, HGSLH, and HGSRH, respectively. All subjects were divided into 5 grades according to HGS.

Results

Muscle strength in the dominant, right, and left arms was correlated with variables in the order of sex, weight, age, height, Xc/H, and R/H (all, p < 0.001). Using all 6 variables, the determination coefficients were 0.792, 0.782, and 0.745, respectively, whereas the standard errors of estimates were 56.89, 58.01, and 56.67 N for HGSDH, HGSLH, and HGSRH, respectively. HGS was positively correlated with PhA, and negatively correlated with Xc/H and R/H.

Conclusions

BIVA parameters measured with a standing impedance analyzer and anthropometric variables can predict and discriminate muscle function with good performance in healthy Asian adults.

SUBMITTER: Lee LW 

PROVIDER: S-EPMC7292401 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Prediction and discrimination of skeletal muscle function by bioelectrical impedance vector analysis using a standing impedance analyzer in healthy Taiwanese adults.

Lee Li-Wen LW   Lu Hsueh-Kuan HK   Chen Yu-Yawn YY   Lai Chung-Liang CL   Chu Lee-Ping LP   Hsieh Meng-Che MC   Hsieh Kuen-Chang KC  

PloS one 20200612 6


<h4>Background</h4>Bioelectrical impedance vector analysis (BIVA) has been used for prediction of muscle performance. However, little is known about BIVA in Asian adults, and even less is known about using standing BIVA devices. Standing impedance analyzer allows quicker and more convenient way to gather data than conventional supine analyzer and is more suitable for clinical practice. This study aimed to investigate the relations between muscle function and BIVA parameters measured with a stand  ...[more]

Similar Datasets

| S-EPMC6676004 | biostudies-literature
| S-EPMC6345442 | biostudies-literature
| S-EPMC7035056 | biostudies-literature
| S-EPMC7113534 | biostudies-literature
| S-EPMC5861891 | biostudies-literature
| S-EPMC10021121 | biostudies-literature
| S-EPMC6024648 | biostudies-literature
| S-EPMC5991700 | biostudies-literature
| S-EPMC11366593 | biostudies-literature
| S-EPMC6950502 | biostudies-literature