A flexible and physically transient electrochemical sensor for real-time wireless nitric oxide monitoring.


ABSTRACT: Real-time sensing of nitric oxide (NO) in physiological environments is critically important in monitoring neurotransmission, inflammatory responses, cardiovascular systems, etc. Conventional approaches for NO detection relying on indirect colorimetric measurement or built with rigid and permanent materials cannot provide continuous monitoring and/or require additional surgical retrieval of the implants, which comes with increased risks and hospital cost. Herein, we report a flexible, biologically degradable and wirelessly operated electrochemical sensor for real-time NO detection with a low detection limit (3.97 nmol), a wide sensing range (0.01-100 ?M), and desirable anti-interference characteristics. The device successfully captures NO evolution in cultured cells and organs, with results comparable to those obtained from the standard Griess assay. Incorporated with a wireless circuit, the sensor platform achieves continuous sensing of NO levels in living mammals for several days. The work may provide essential diagnostic and therapeutic information for health assessment, treatment optimization and postsurgical monitoring.

SUBMITTER: Li R 

PROVIDER: S-EPMC7316789 | biostudies-literature | 2020 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

A flexible and physically transient electrochemical sensor for real-time wireless nitric oxide monitoring.

Li Rongfeng R   Qi Hui H   Ma Yuan Y   Deng Yuping Y   Liu Shengnan S   Jie Yongsheng Y   Jing Jinzhu J   He Jinlong J   Zhang Xu X   Wheatley Laura L   Huang Congxi C   Sheng Xing X   Zhang Milin M   Yin Lan L  

Nature communications 20200625 1


Real-time sensing of nitric oxide (NO) in physiological environments is critically important in monitoring neurotransmission, inflammatory responses, cardiovascular systems, etc. Conventional approaches for NO detection relying on indirect colorimetric measurement or built with rigid and permanent materials cannot provide continuous monitoring and/or require additional surgical retrieval of the implants, which comes with increased risks and hospital cost. Herein, we report a flexible, biological  ...[more]

Similar Datasets

| S-EPMC6759084 | biostudies-literature
| S-EPMC5479482 | biostudies-literature
| S-EPMC6404975 | biostudies-literature
| S-EPMC9296503 | biostudies-literature
| S-EPMC6971339 | biostudies-literature
| S-EPMC8151083 | biostudies-literature
| S-EPMC6392066 | biostudies-literature
| S-EPMC2715559 | biostudies-literature
| S-EPMC7147171 | biostudies-literature
| S-EPMC8220094 | biostudies-literature