Unknown

Dataset Information

0

Evaluation of the RealStar® SARS-CoV-2 RT-PCR kit RUO performances and limit of detection.


ABSTRACT: BACKGROUND:The use of efficient, reliable and sensitive PCR assays is a cornerstone in the race to contain the SARS-CoV-2 pandemic. In this work we performed an independent evaluation of the RealStar® SARS-CoV-2 RT-PCR Kit Researh Use Only (Altona) for SARS-CoV-2 detection. METHODS:A comparative limit of detection (LoD) assessment was performed between RealStar® SARS-CoV-2 and the currently WHO recommended RT-PCR (WHO-PCR) workflow using a quantified clinical sample. Assessment of the RealStar® SARS-CoV-2 assay was also performed using 83 primary clinical samples in comparison with the WHO-PCR. RESULTS:The RealStar® SARS-CoV-2 demonstrated a slightly higher sensitivity than the WHO recommended assay with a limit of detection at 625 copies/mL instead of 1250 copies/mL for the WHO-PCR in our conditions. The overall percent agreement between RealStar® SARS-CoV-2 and WHO-PCR on 83 clinical samples was 97.6 % (81/83) with a sensitivity at 97.8 % (45/46) and specificity at 97.3 % (36/37). No cross reaction was encountered for the other human coronaviruses (HKU1, OC43, NL63, 229E). CONCLUSIONS:In this comparison of the RealStar® SARS-CoV-2 assay with the reference WHO assay, we observed a slightly better sensitivity of the RealStar® assay. It provides a robust option for all molecular biology laboratories, with a strong real-life LoD and is compatible with various real-time PCR platforms.

SUBMITTER: Visseaux B 

PROVIDER: S-EPMC7323686 | biostudies-literature | 2020 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of the RealStar® SARS-CoV-2 RT-PCR kit RUO performances and limit of detection.

Visseaux Benoit B   Le Hingrat Quentin Q   Collin Gilles G   Ferré Valentine V   Storto Alexandre A   Ichou Houria H   Bouzid Donia D   Poey Nora N   de Montmollin Etienne E   Descamps Diane D   Houhou-Fidouh Nadhira N  

Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology 20200629


<h4>Background</h4>The use of efficient, reliable and sensitive PCR assays is a cornerstone in the race to contain the SARS-CoV-2 pandemic. In this work we performed an independent evaluation of the RealStar® SARS-CoV-2 RT-PCR Kit Researh Use Only (Altona) for SARS-CoV-2 detection.<h4>Methods</h4>A comparative limit of detection (LoD) assessment was performed between RealStar® SARS-CoV-2 and the currently WHO recommended RT-PCR (WHO-PCR) workflow using a quantified clinical sample. Assessment of  ...[more]

Similar Datasets

| S-EPMC8228578 | biostudies-literature
| S-EPMC7666399 | biostudies-literature
| S-EPMC6161464 | biostudies-literature
| S-EPMC8830688 | biostudies-literature
| S-EPMC9481164 | biostudies-literature
| S-EPMC2738119 | biostudies-literature
| S-EPMC6803750 | biostudies-literature
| S-EPMC8673714 | biostudies-literature
| S-EPMC7172518 | biostudies-literature
| S-EPMC5405276 | biostudies-literature