Ontology highlight
ABSTRACT: Background
Although a mixture of pigments and radiopaque materials was reported to be useful material for lung nodule localization, the optimal combination has not been well investigated. The purpose of this study is to evaluate the characteristics of various combinations of pigments and radiopaque materials for localization of pulmonary nodules prior to video-assisted thoracic surgery (VATS).Methods
We compared stability, viscosity, and visibility of 6 radiopaque dye materials of (I) mixture of indigo carmine and lipiodol; (II) mixture of indigo carmine, lipiodol, and lidocaine gel; (III) mixture of indocyanine green in water solution (w-ICG) and lipiodol; (IV) mixture of w-ICG, lipiodol, and lidocaine gel; (V) ICG in contrast medium solution (cm-ICG); and (VI) mixture of cm-ICG and lidocaine gel. Stability was evaluated by observing changes in the mixtures in the test tube with time visually and radiographically. Viscosities were measured by rotational viscometer. Materials were injected into an expanded pig-lung phantom, and area on CT and visibility on thoracoscopy camera were evaluated.Results
Separation could be seen 15 min after preparation in (I) and (III), and 1 h after preparation in (II), both visually and radiographically. In (IV), separation could be seen on the photographs but not on the X-ray images from 3 h after preparation. (V) and (VI) showed no changes within the 2-day observation period. The viscosities of the materials were (I) 0.2±0.1, (II) 2.9±0.1, (III) 0.2±0.1, (IV) 2.6±0.1, (V) 0.2±0.1, and (VI) 1.2±0.1 dPa·s. The area on CT showed very strong negative correlation with viscosity (r=-0.97). The injection point of each material was easily detected on thoracoscopy camera.Conclusions
Radiopaque dye materials appear useful for localizing pulmonary nodules before VATS; their diffusion in the lung parenchyma can be suppressed by using materials of high viscosity.
SUBMITTER: Hasegawa T
PROVIDER: S-EPMC7330362 | biostudies-literature | 2020 May
REPOSITORIES: biostudies-literature
Journal of thoracic disease 20200501 5
<h4>Background</h4>Although a mixture of pigments and radiopaque materials was reported to be useful material for lung nodule localization, the optimal combination has not been well investigated. The purpose of this study is to evaluate the characteristics of various combinations of pigments and radiopaque materials for localization of pulmonary nodules prior to video-assisted thoracic surgery (VATS).<h4>Methods</h4>We compared stability, viscosity, and visibility of 6 radiopaque dye materials o ...[more]