Unknown

Dataset Information

0

High Enantiomeric Excess In-Loop Synthesis of d-[methyl-11C]Methionine for Use as a Diagnostic Positron Emission Tomography Radiotracer in Bacterial Infection.


ABSTRACT: Currently, there exists no accurate, noninvasive clinical imaging method to detect living bacteria in vivo. Our goal is to provide a positron emission tomography (PET) method to image infection by targeting bacteria-specific metabolism. Standard of care methodologies detect morphologic changes, image immunologic response to infection, or employ invasive tissue sampling with associated patient morbidity. These strategies, however, are not specific for living bacteria and are often inadequate to detect bacterial infection during fever workup. As such, there is an unmet clinical need to identify and validate new imaging tools suitable for noninvasive, in vivo (PET) imaging of living bacteria. We have shown that d-[methyl-11C]methionine (d-[11C]Met) can distinguish active bacterial infection from sterile inflammation in a murine infection model and is sensitive to both Gram-positive and Gram-negative bacteria. Here, we report an automated and >99% enantiomeric excess (ee) synthesis of d-[11C]Met from a linear d-homocysteine precursor, a significant improvement over the previously reported synthesis utilizing a d-homocysteine thiolactone hydrochloride precursor with approximately 75-85% ee. Furthermore, we took additional steps toward applying d-[11C]Met to infected patients. d-[11C]Met was subject to a panel of clinically relevant bacterial strains and demonstrated promising sensitivity to these pathogens. Finally, we performed radiation dosimetry in a normal murine cohort to set the stage for translation to humans in the near future.

SUBMITTER: Stewart MN 

PROVIDER: S-EPMC7364312 | biostudies-literature | 2020 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

High Enantiomeric Excess In-Loop Synthesis of d-[methyl-<sup>11</sup>C]Methionine for Use as a Diagnostic Positron Emission Tomography Radiotracer in Bacterial Infection.

Stewart Megan N MN   Parker Matthew F L MFL   Jivan Salma S   Luu Justin M JM   Huynh Tony L TL   Schulte Brailee B   Seo Youngho Y   Blecha Joseph E JE   Villanueva-Meyer Javier E JE   Flavell Robert R RR   VanBrocklin Henry F HF   Ohliger Michael A MA   Rosenberg Oren O   Wilson David M DM  

ACS infectious diseases 20191121 1


Currently, there exists no accurate, noninvasive clinical imaging method to detect living bacteria <i>in vivo</i>. Our goal is to provide a positron emission tomography (PET) method to image infection by targeting bacteria-specific metabolism. Standard of care methodologies detect morphologic changes, image immunologic response to infection, or employ invasive tissue sampling with associated patient morbidity. These strategies, however, are not specific for living bacteria and are often inadequa  ...[more]

Similar Datasets

| S-EPMC7786890 | biostudies-literature
| S-EPMC3049488 | biostudies-other
| S-EPMC3690440 | biostudies-literature
| S-EPMC6360528 | biostudies-literature
| S-EPMC3966281 | biostudies-literature
| S-EPMC6045447 | biostudies-literature
| S-EPMC8467059 | biostudies-literature
| S-EPMC7046493 | biostudies-literature
| S-EPMC8590058 | biostudies-literature
2015-02-09 | E-MTAB-3175 | biostudies-arrayexpress