Multimode ultrasound viscoelastography for three-dimensional interrogation of microscale mechanical properties in heterogeneous biomaterials.


ABSTRACT: Both static and time-dependent mechanical factors can have a profound impact on cell and tissue function, but it is challenging to measure the mechanical properties of soft materials at the scale which cells sense. Multimode ultrasound viscoelastography (MUVE) uses focused ultrasound pulses to both generate and image deformations within soft hydrogels non-invasively, at sub-millimeter resolution, and in 3D. The deformation and strain over time data are used to extract quantitative parameters that describe both the elastic and viscoelastic properties of the material. MUVE was used in creep mode to characterize the viscoelastic properties of 3D agarose, collagen, and fibrin hydrogels. Quantitative comparisons were made by extracting characteristic viscoelastic parameters using Burger's lumped parameter constitutive model. Spatial resolution of the MUVE technique was found to be approximately 200??m, while detection sensitivity, defined as the capability to differentiate between materials based on mechanical property differences, was approximately 0.2?kPa using agarose hydrogels. MUVE was superior to nanoindentation and shear rheometry in generating consistent microscale measurements of viscoelastic behavior in soft materials. These results demonstrate that MUVE is a rapid, quantitative, and accurate method to measure the viscoelastic mechanical properties of soft 3D hydrogels at the microscale, and is a promising technique to study the development of native and engineered tissues over time.

SUBMITTER: Hong X 

PROVIDER: S-EPMC7369000 | biostudies-literature | 2018 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Multimode ultrasound viscoelastography for three-dimensional interrogation of microscale mechanical properties in heterogeneous biomaterials.

Hong Xiaowei X   Annamalai Ramkumar T RT   Kemerer Tyler S TS   Deng Cheri X CX   Stegemann Jan P JP  

Biomaterials 20180602


Both static and time-dependent mechanical factors can have a profound impact on cell and tissue function, but it is challenging to measure the mechanical properties of soft materials at the scale which cells sense. Multimode ultrasound viscoelastography (MUVE) uses focused ultrasound pulses to both generate and image deformations within soft hydrogels non-invasively, at sub-millimeter resolution, and in 3D. The deformation and strain over time data are used to extract quantitative parameters tha  ...[more]

Similar Datasets

| S-EPMC4792732 | biostudies-literature
| S-EPMC4424696 | biostudies-literature
| S-EPMC3534971 | biostudies-literature
| S-EPMC7591493 | biostudies-literature
| S-EPMC8270165 | biostudies-literature
| S-EPMC9314325 | biostudies-literature
| S-EPMC3758562 | biostudies-literature
| S-EPMC6731457 | biostudies-literature
| S-EPMC9961517 | biostudies-literature
| S-EPMC7164496 | biostudies-literature